A silent echo-planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis

Publication date

2024-06

Authors

Versteeg, EdwinORCID 0000-0003-3235-3970
Nam, Kyung Min
Klomp, Dennis W.J.ORCID 0000-0002-5884-5386ISNI 0000000396514008
Bhogal, Alex AORCID 0000-0003-3211-1760
Siero, J. C.W.ORCID 0000-0001-5079-2868ISNI 0000000394978810
Wijnen, JannieORCID 0000-0003-2352-3667ISNI 0000000387155509

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Purpose: We present a novel silent echo-planar spectroscopic imaging (EPSI) readout, which uses an ultrasonic gradient insert to accelerate MRSI while producing a high spectral bandwidth (20 kHz) and a low sound level. Methods: The ultrasonic gradient insert consisted of a single-axis (z-direction) plug-and-play gradient coil, powered by an audio amplifier, and produced 40 mT/m at 20 kHz. The silent EPSI readout was implemented in a phase-encoded MRSI acquisition. Here, the additional spatial encoding provided by this silent EPSI readout was used to reduce the number of phase-encoding steps. Spectroscopic acquisitions using phase-encoded MRSI, a conventional EPSI-readout, and the silent EPSI readout were performed on a phantom containing metabolites with resonance frequencies in the ppm range of brain metabolites (0–4 ppm). These acquisitions were used to determine sound levels, showcase the high spectral bandwidth of the silent EPSI readout, and determine the SNR efficiency and the scan efficiency. Results: The silent EPSI readout featured a 19-dB lower sound level than a conventional EPSI readout while featuring a high spectral bandwidth of 20 kHz without spectral ghosting artifacts. Compared with phase-encoded MRSI, the silent EPSI readout provided a 4.5-fold reduction in scan time. In addition, the scan efficiency of the silent EPSI readout was higher (82.5% vs. 51.5%) than the conventional EPSI readout. Conclusions: We have for the first time demonstrated a silent spectroscopic imaging readout with a high spectral bandwidth and low sound level. This sound reduction provided by the silent readout is expected to have applications in sound-sensitive patient groups, whereas the high spectral bandwidth could benefit ultrahigh-field MR systems.

Keywords

EPSI, gradient insert, MRSI, quiet, silent, spectroscopy, Radiology Nuclear Medicine and imaging

Citation

Versteeg, E, Nam, K M, Klomp, D W J, Bhogal, A A, Siero, J C W & Wijnen, J P 2024, 'A silent echo-planar spectroscopic imaging readout with high spectral bandwidth MRSI using an ultrasonic gradient axis', Magnetic Resonance in Medicine, vol. 91, no. 6, pp. 2247-2256. https://doi.org/10.1002/mrm.30008