Functional Echocardiographic and Serum Biomarker Changes Following Surgical and Percutaneous Atrial Septal Defect Closure in Children

Publication date

2022-08-16

Authors

van der Ven, J. P.G.
van den Bosch, E.
Kamphuis, V. P.
Terol, Covadonga
Gnanam, Devi
Bogers, Ad J J C
Breur, Johannes M P JISNI 0000000395622111
Berger, Rolf M F
Blom, Nico A
Koopman, Laurens

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc

Abstract

Background Ventricular performance is temporarily reduced following surgical atrial septal defect closure. Cardiopulmonary bypass and changes in loading conditions are considered important factors, but this phenomenon is incompletely understood. We aim to characterize biventricular performance following surgical and percutaneous atrial septal defect closure and to relate biomarkers to ventricular performance following intervention. Methods and Results In this multicenter prospective study, children scheduled for surgical or percutaneous atrial septal defect closure were included. Subjects were assessed preoperatively, in the second week postintervention (at 2-weeks follow-up), and 1-year postintervention (1-year follow-up). At each time point, an echocardiographic study and a panel of biomarkers were obtained. Sixty-three patients (median age, 4.1 [interquartile range, 3.1-6.1] years) were included. Forty-three patients underwent surgery. At 2-weeks follow-up, right ventricular global longitudinal strain was decreased for the surgical, but not the percutaneous, group (-17.6±4.1 versus -27.1±3.4; P<0.001). A smaller decrease was noted for left ventricular global longitudinal strain at 2-weeks follow-up for the surgical group (surgical versus percutaneous, -18.6±3.2 versus -20.2±2.4; P=0.040). At 1-year follow-up, left ventricular performance returned to baseline, whereas right ventricular performance improved, but did not reach preintervention levels. Eight biomarkers relating to cardiovascular and immunological processes differed across study time points. Of these biomarkers, only NT-proBNP (N-terminal pro-B-type natriuretic peptide) correlated with less favorable left ventricular global longitudinal strain at 2-weeks follow-up. Conclusions Right, and to a lesser degree left, ventricular performance was reduced early after surgical atrial septal defect closure. Right ventricular performance at 1-year follow-up remained below baseline levels. Several biomarkers showed a pattern over time similar to ventricular performance. These biomarkers may provide insight into the processes that affect ventricular function. Registration URL: https://www.trialregister.nl/; Unique identifier: NL5129.

Keywords

atrial septal defects, biomarkers, cardiopulmonary bypass, congenital heart disease, speckle tracking echocardiography, Cardiology and Cardiovascular Medicine

Citation

van der Ven, J P G, van den Bosch, E, Kamphuis, V P, Terol, C, Gnanam, D, Bogers, A J J C, Breur, J M P J, Berger, R M F, Blom, N A, Koopman, L, Ten Harkel, A D J & Helbing, W A 2022, 'Functional Echocardiographic and Serum Biomarker Changes Following Surgical and Percutaneous Atrial Septal Defect Closure in Children', Journal of the American Heart Association, vol. 11, no. 16, e024072, pp. 1-13. https://doi.org/10.1161/JAHA.121.024072