Online adaptive MR-guided radiotherapy: Conformity of contour adaptation for prostate cancer, rectal cancer and lymph node oligometastases among radiation therapists and radiation oncologists

Publication date

2022-09

Authors

Rasing, Marnix J A
Sikkes, Gonda G
Vissers, Nicole G P M
Kotte, Alexis N.T.J.ISNI 0000000395467270
Boudewijn, Joske H
Doornaert, P A HISNI 0000000392515134
Eppinga, Wietse S CISNI 0000000389239685
Intven, M. P.W.ORCID 0000-0002-5068-5517ISNI 0000000393019546
Rutgers, Reijer H A
Scheeren, Annick

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Background and purpose: Online adaptive MR-guided treatment planning workflows facilitate daily contour adaptation to the actual anatomy. Allocating contour adaptation to radiation therapists (RTTs) instead of radiation oncologists (ROs) might allow for increasing workflow efficiency. This study investigates conformity of adapted target contours provided by dedicated RTTs and ROs. Materials and methods: In a simulated online procedure, 6 RTTs and 6 ROs recontoured targets and organs at risk (OAR) in prostate cancer (n = 2), rectal cancer (n = 2) and lymph node-oligometastases (n = 2) cases. RTTs gained contouring competence beforehand by following a specific in-house training program. For all target contours and the reference delineations volumetric differences were determined and Dice similarity coefficient (DSC), conformity index (CI) and generalized CI were calculated. Delineation time and -confidence were registered for targets and OAR. Impact of contour adaptation on treatment plan quality was investigated. Results: Delineation conformity was generally high with DSC, CI and generalized CI values in the range of 0.81-0.94, 0.87-0.95 and 0.63-0.85 for prostate cancer, rectal cancer and LN-oligometastasis, respectively. Target volumes were comparable for both, RTTs and ROs. Time needed and confidence in contour adaptation was comparable as well. Treatment plans derived with adapted contours did not violate dose volume constrains as used in clinical routine. Conclusion: After tumor site specific training, daily contour adaptations as needed in adaptive online radiotherapy workflows can be accurately performed by RTTs. Conformity of the derived contours is high and comparable to contours as provided by ROs.

Keywords

Adaptive, Conformity, Delineation, Image-guided radiation, MR-guided radiotherapy, MR-Linac, Care Planning, Oncology(nursing), Health Policy, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Rasing, M J A, Sikkes, G G, Vissers, N G P M, Kotte, A N T J, Boudewijn, J H, Doornaert, P A H, Eppinga, W S C, Intven, M, Rutgers, R H A, Scheeren, A, Snoeren, L M W, Vlig, T B, van der Voort van Zyp, J R N, Wijkhuizen, L M, van Rossum, P S N, Peters, M & Jürgenliemk-Schulz, I M 2022, 'Online adaptive MR-guided radiotherapy : Conformity of contour adaptation for prostate cancer, rectal cancer and lymph node oligometastases among radiation therapists and radiation oncologists', Technical innovations & patient support in radiation oncology, vol. 23, pp. 33-40. https://doi.org/10.1016/j.tipsro.2022.08.004