A mask-compatible, radiolucent, 8-channel head and neck receive array for MRI-guided radiotherapy treatments and pre-treatment simulation
Publication date
2022-06-24
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
No license information available
Abstract
Immobilization masks are used to prevent patient movement during head and neck (H&N) radiotherapy. Motion restriction is beneficial both during treatment, as well as in the pre-treatment simulation phase, where magnetic resonance imaging (MRI) is often used for target definition. However, the shape and size of the immobilization masks hinder the use of regular, close-fitting MRI receive arrays. In this work, we developed a mask-compatible 8-channel H&N array that consists of a single-channel baseplate, on which the mask can be secured, and a flexible 7-channel anterior element that follows the shape of the mask. The latter uses high impedance coils to achieve its flexibility and radiolucency. A fully-functional prototype was manufactured, its radiolucency was characterized, and the gain in imaging performance with respect to current clinical setups was quantified. Dosimetry measurements showed an overall dose change of -0.3%. Small, local deviations were up to -2.7% but had no clinically significant impact on a full treatment plan, as gamma pass rates (3%/3 mm) only slightly reduced from 97.9% to 97.6% (clinical acceptance criterion: ≥95%). The proposed H&N array improved the imaging performance with respect to three clinical setups. The H&N array more than doubled (+123%) and tripled (+246%) the signal-to-noise ratio with respect to the clinical MRI-simulation and MR-linac setups, respectively. G-factors were also lower with the proposed H&N array. The improved imaging performance resulted in a clearly visible signal-to-noise ratio improvement of clinically used TSE and DWI acquisitions. In conclusion, the 8-channel H&N array improves the imaging performance of MRI-simulation and MR-linac acquisitions, while dosimetry suggests that no clinically significant dose changes are induced.
Keywords
Head, Humans, MR-linac, MRI-guided radiotherapy, MRI-simulation, Magnetic Resonance Imaging, Particle Accelerators, Phantoms, Imaging, Radiotherapy, Image-Guided, Signal-To-Noise Ratio, head and neck, mask-compatible, radiolucent receive array, Taverne, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging, Research Support, Non-U.S. Gov't, Journal Article
Citation
Zijlema, S E, Breimer, W, Gosselink, M W J M, Bruijnen, T, Arteaga de Castro, C S, Tijssen, R H N, Lagendijk, J J W, Philippens, M E P & Van den Berg, C A T 2022, 'A mask-compatible, radiolucent, 8-channel head and neck receive array for MRI-guided radiotherapy treatments and pre-treatment simulation', Physics in medicine and biology, vol. 67, no. 13, 135006, pp. 1-14. https://doi.org/10.1088/1361-6560/ac6ebd