The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis): Angiographic Results and 1-Year Clinical Outcomes

Publication date

2017-10-23

Authors

Verheye, Stefan
Vrolix, Mathias
Kumsars, Indulis
Erglis, Andrejs
Sondore, Dace
Agostoni, PiefrancescoISNI 0000000388177910
Cornelis, Kristoff
Janssens, Luc P F
Maeng, Michael
Slagboom, Ton

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Objectives The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR). Background Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR. Methods In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinical follow-up. Results Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE. Conclusions This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinical outcomes that warrant further evaluation in dedicated randomized studies.

Keywords

drug-eluting balloon, extended release, in-stent restenosis, porous angioplasty balloon, sirolimus nanoparticle, Taverne, Cardiology and Cardiovascular Medicine, Journal Article

Citation

Verheye, S, Vrolix, M, Kumsars, I, Erglis, A, Sondore, D, Agostoni, P, Cornelis, K, Janssens, L P F, Maeng, M, Slagboom, T, Amoroso, G, Jensen, L O, Granada, J F & Stella, P 2017, 'The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis) : Angiographic Results and 1-Year Clinical Outcomes', JACC. Cardiovascular Interventions, vol. 10, no. 20, pp. 2029-2037. https://doi.org/10.1016/j.jcin.2017.06.021