Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting: A Randomized Controlled Trial (ADVISE-CRT III)

Publication date

2025-06

Authors

Gerrits, Willem
Wouters, Philippe C
Chiu, Cheyenne S L
Guglielmo, MarcoORCID 0000-0003-1718-9949
Cramer, Maarten JanISNI 0000000390984527
van der Harst, PimORCID 0000-0002-2713-686X
Vernooy, Kevin
van Stipdonk, Antonius M W
van Halm, Vokko P
van Dijk, Vincent F

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Background: To improve cardiac resynchronization therapy (CRT) an on-screen image-guidance platform, CARTBox-Suite (CART-Tech B.V.), was developed to identify left ventricular pacing electrode (LVPE) implantation sites and facilitate precise LVPE placement. This multicenter randomized trial evaluated the efficacy of image guidance on LVPE implantation accuracy and its impact on left ventricular end-systolic volume (LVESV) reduction 6 months after CRT. Objectives: The aim of this trial is to improve the accuracy and efficacy of LVPE placement in CRT. Methods: A total of 131 heart failure patients (80% with Class I CRT indication) were enrolled across 7 hospitals in the Netherlands. CARTBox-Suite, which utilizes a cloud-based AI algorithm, was used to identify a target area with late mechanical activation based on cardiac magnetic resonance imaging. Scarred areas marked by late gadolinium enhancement were excluded. Patients were randomized to image-guided implantation, with on-screen guidance during the procedure or conventional implantation. Results: The primary endpoint, LVPE implantation in the target area, was achieved significantly more often in the image-guided group (66.7% vs 29.2%; P < 0.001). The secondary endpoint was fewer LVPE placed in scarred areas in the image-guided group (7.1% vs 36.4%; P = 0.006). Mean LVESV reduction was greater in the image-guided group (43.2% vs. 37.6%), although not significantly (P = 0.166). Patients with myocardial scar showed greater LVESV reduction with image guidance (40.7% vs 27.7%; P = 0.028). Conclusions: Image-guided implantation resulted in significantly more LVPE placed in the target area and greater LVESV reduction in patients with myocardial scar.

Keywords

cardiac resynchronization therapy, heart failure, image guidance, magnetic resonance imaging, precision medicine, Cardiology and Cardiovascular Medicine, Physiology (medical)

Citation

Gerrits, W, Wouters, P C, Chiu, C S L, Guglielmo, M, Cramer, M J, van der Harst, P, Vernooy, K, van Stipdonk, A M W, van Halm, V P, van Dijk, V F, Ghani, A, Maass, A H, Yap, S-C, van Slochteren, F J & Meine, M 2025, 'Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting : A Randomized Controlled Trial (ADVISE-CRT III)', JACC. Clinical electrophysiology, vol. 11, no. 6, pp. 1293-1305. https://doi.org/10.1016/j.jacep.2025.01.022