The effects of CO<inf>2</inf>-insufflation with 5 and 10 mmHg during thoracoscopy on cerebral oxygenation and hemodynamics in piglets: an animal experimental study
Files
Publication date
2015-09
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
Abstract
Objective: To evaluate the effect of CO<inf>2</inf>-insufflation with 5 and 10 mmHg on cerebral oxygenation and hemodynamics in neonates. Background: An increasing percentage of surgical interventions in neonates are performed by minimal invasive techniques. Recently, concerns have been raised regarding a decrease of cerebral oxygenation in neonates during thoracoscopy as a result of CO<inf>2</inf>-insufflation. Methods: This was an animal experimental study. Piglets were anesthetized, intubated, ventilated, and surgically prepared for CO<inf>2</inf>-insufflation. Insufflation was done with 5 or 10 mmHg CO<inf>2</inf> during 1 h. Arterial saturation (SaO<inf>2</inf>), heart rate (HR), mean arterial blood pressure (MABP), and cerebral oxygenation (rScO<inf>2</inf>) were monitored. CFTOE, an estimator of cerebral oxygen extraction ((SaO<inf>2</inf> − rScO<inf>2</inf>)/SaO<inf>2</inf>)), was calculated. Arterial blood gases were drawn every 15′: pre (T0), during (T1-T4) and after CO<inf>2</inf>-insufflation (T5). Results: Ten piglets (4 kg) were randomized for 5 (P5) and 10 (P10) mmHg CO<inf>2</inf>-insufflation. Two P10 piglets needed resuscitation after insufflation, none P5. Linear mixed-effect modeling of paCO<inf>2</inf>, pH, and SaO<inf>2</inf> showed that values were dependent on time and time squared (p < 0.001) but were not different between the 5 and 10 mmHg groups. Analysis demonstrated significant changes over time in heart rate and MABP between the 5 and 10 mmHg groups, with a significant higher heart rate and lower blood pressure in the 10 mmHg group (p < 0.001). For rScO<inf>2</inf> and cFTOE, no group differences could be demonstrated, but a significant effect of time was found: rScO<inf>2</inf> increased and cFTOE decreased (p < 0.001). Conclusions: Insufflation of CO<inf>2</inf> during thoracoscopy with 10 mmHg caused more severe hemodynamic instability and seems to be related with a decrease of cerebral perfusion as represented by a higher oxygen extraction. CO<inf>2</inf>-insufflation of 5 mmHg for thoracoscopy seems to have no adverse effects on cerebral oxygenation.
Keywords
Cerebral oxygenation, CO2, Endoscopy, Esophageal atresia, Neonatal surgery, Pediatric, Thoracoscopy, Surgery
Citation
Stolwijk, L J, Tytgat, S H A J, Keunen, K, Suksamanapan, N, van Herwaarden, M Y A, Groenendaal, F, Lemmers, P M A & van der Zee, D C 2015, 'The effects of CO <inf >2 </inf >-insufflation with 5 and 10 mmHg during thoracoscopy on cerebral oxygenation and hemodynamics in piglets : an animal experimental study', Surgical Endoscopy, vol. 29, no. 9, pp. 2781-2788. https://doi.org/10.1007/s00464-014-4009-5