Artificial atrial fibrillation in the dog. An artifact?

Publication date

1971-04

Authors

Strackee, J.
Hoelen, A.J.
Zimmerman, A.N.E.
Meijler, F.L.

Editors

Advisors

Supervisors

DOI

Document Type

Article
Open Access logo

License

Abstract

R-R interval sequences during artificial atrial fibrillation in dogs were studied in the same way as in patients in a previous study and compared with results obtained in dogs with spontaneous atrial fibrillation. Artificial atrial fibrillation was effected by right atrial stimulation in three closed-chest and one open-chest dog. The ventricular rhythm was studied by histograms and autocorrelograms. The ventricular dysrhythmia dming artificial atrial fibrillation generally differed from that during h'ue atrial fibrillation. Therefore the findings during artificial atrial fibrillation cannot be used without reservation to explain electrophysiologic al (or hemodynamic) phenomena in true atrial fibrillation.

Keywords

atrial fibrillation, artificial atrial fibrillation, dogs

Citation