Prostate tumor delineation using multiparametric magnetic resonance imaging: Inter-observer variability and pathology validation

Publication date

2015-05

Authors

Steenbergen, Peter
Haustermans, Karin
Lerut, Evelyne
Oyen, Raymond
De Weyer, Liesbeth
Van den Bergh, Laura
Kerkmeijer, Linda G WISNI 0000000393809169
Pameijer, Frank AISNI 0000000087442565
Veldhuis, WBORCID 0000-0002-9798-6843ISNI 0000000395578034
van der Voort van Zyp, Jochem R NISNI 0000000393775683

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Background and purpose: Boosting the dose to the largest (dominant) lesion in radiotherapy of prostate cancer may improve treatment outcome. The success of this approach relies on the detection and delineation of tumors. The agreement among teams of radiation oncologists and radiologists delineating lesions on multiparametric magnetic resonance imaging (mp-MRI) was assessed by measuring the distances between observer contours. The accuracy of detection and delineation was determined using whole-mount histopathology specimens as reference. Material and methods: Six observer teams delineated tumors on mp-MRI of 20 prostate cancer patients who underwent a prostatectomy. To assess the inter-observer agreement, the inter-observer standard deviation (SD) of the contours was calculated for tumor sites which were identified by all teams. Results: Eighteen of 89 lesions were identified by all teams, all were dominant lesions. The median histological volume of these was 2.4 cm(3). The median inter-observer SD of the delineations was 0.23 cm. Sixty-six of 69 satellites were missed by all teams. Conclusion: Since all teams identify most dominant lesions, dose escalation to the dominant lesion is feasible. Sufficient dose to the whole prostate may need to be maintained to prevent under treatment of smaller lesions and undetected parts of larger lesions. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.

Keywords

Prostate cancer, Radiotherapy, Tumor delineation, Multiparametric MRI, Dose escalation, Inter-observer variability, WHOLE-MOUNT HISTOPATHOLOGY, SIMULTANEOUS INTEGRATED BOOST, CANCER, MRI, THERAPY, RADIOTHERAPY, METAANALYSIS, PARAMETERS, LESIONS, Taverne

Citation

Steenbergen, P, Haustermans, K, Lerut, E, Oyen, R, De Weyer, L, Van den Bergh, L, Kerkmeijer, LGW, Pameijer, FA, Veldhuis, WB, van der Voort van Zyp, J, Pos, F J, Heijmink, S W, Kalisvaart, R, Teertstra, H J, Dinh, C V, Ghobadi, G & van der Heide, U A 2015, 'Prostate tumor delineation using multiparametric magnetic resonance imaging : Inter-observer variability and pathology validation', Radiotherapy & Oncology, vol. 115, no. 2, pp. 186-190. https://doi.org/10.1016/j.radonc.2015.04.012