A quantitative comparison of anti-Müllerian hormone measurement and its shifting boundaries between two assays

Publication date

2017-07-01

Authors

de Kat, Annelien C
Broekmans, FrankISNI 0000000395585824
van Westing, A. C.
Lentjes, Eef G WISNI 0000000391467521
Verschuren, W. M.MoniqueISNI 0000000140365125
van der Schouw, Yvonne TORCID 0000-0002-4605-435XISNI 0000000140542144

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Objective Anti-Müllerian hormone (AMH), a quantitative marker of ovarian reserve, is used for both clinical and research purposes in the field of reproductive medicine. Numerous AMH assays have been developed. Among other factors, the lack of large-scale comparisons of the various assays hinders the universal interpretation of AMH levels. Moreover, little is known of the practical performance of highly sensitive assays compared with conventional assays with regard to the very low AMH levels found in women nearing menopause. This study aimed to compare the measurements of the Gen II (Beckman Coulter) assay with those of the highly sensitive picoAMH (AnshLabs) assay. Methods This cross-sectional study included 1985 premenopausal women who completed the second visit of the population-based Doetinchem Cohort Study, with a mean age of 42 ± 7 years. AMH levels were measured with the Gen II and picoAMH assays. Passing-Bablok and Bland Altman analyses were performed and differences in the proportion of detectable samples were assessed. Results The results from the Gen II and picoAMH assays were highly correlated, with a Spearman correlation coefficient of 0.91. The Passing-Bablok regression formula was picoAMH = 0.01 + 1.69 * GenII, meaning that on average picoAMH levels were 69% higher than Gen II levels. Of the 670 samples with an undetectable AMH value with the Gen II assay, AMH could be detected in 78% with the picoAMH assay, at a median concentration [interquartile range] of 0.05 [0.01–0.14] ng/mL. Conclusion These results indicate that, despite a high correlation, there is a large relative difference between results of the Gen II and picoAMH assays. The use of a highly sensitive AMH assay is likely to result in a large increase in the proportion of samples with detectable levels. This may enable research into women's health across the menopausal transition and research into the potential clinical benefits of distinguishing between women with very low ovarian reserve.

Keywords

Adult, Anti-Mullerian Hormone/blood, Biological Assay, Biomarkers/blood, Cohort Studies, Cross-Sectional Studies, Female, Humans, Middle Aged, Ovarian Reserve, Premenopause/blood, Taverne, General Biochemistry,Genetics and Molecular Biology, Obstetrics and Gynaecology, Comparative Study, Journal Article

Citation

de Kat, A C, Broekmans, F J M, van Westing, A C, Lentjes, E, Verschuren, W M M & van der Schouw, Y T 2017, 'A quantitative comparison of anti-Müllerian hormone measurement and its shifting boundaries between two assays', Maturitas, vol. 101, pp. 12-16. https://doi.org/10.1016/j.maturitas.2017.04.004