Mixed-Bed Ion Exchange Chromatography Employing a Salt-Free pH Gradient for Improved Sensitivity and Compatibility in MudPIT

Files

Access status: Embargo until 2050-01-01 , MommenMixedBedIon.pdf (1009.94 KB)

Publication date

2013

Authors

Mommen, G.P.M.ISNI 0000000524243821
Meiring, H.D.
Heck, AlbertORCID 0000-0002-2405-4404ISNI 0000000393921118
de Jong, A.P.J.M.

Editors

Advisors

Supervisors

Document Type

Article

License

Abstract

In proteomics, comprehensive analysis of peptides mixtures necessitates multiple dimensions of separation prior to mass spectrometry analysis to reduce sample complexity and increase the dynamic range of analysis. The main goal of this work was to improve the performance of (online) multidimensional protein identification technology (MudPIT) in terms of sensitivity, compatibility and recovery. The method employs weak anion and strong cation mixed-bed ion exchange chromatography (ACE) in the first separation dimension and reversed phase chromatography (RP) in the second separation dimension (Motoyama et.al. Anal. Chem 2007, 79, 3623–34.). We demonstrated that the chromatographic behavior of peptides in ACE chromatography depends on both the WAX/SCX mixing ratio as the ionic strength of the mobile phase system. This property allowed us to replace the conventional salt gradient by a (discontinuous) salt-free, pH gradient. First dimensional separation of peptides was accomplished with mixtures of aqueous formic acid and dimethylsulfoxide with increasing concentrations. The overall performance of this mobile phase system was found comparable to ammonium acetate buffers in application to ACE chromatography, but clearly outperformed strong cation exchange for use in first dimensional peptide separation. The dramatically improved compatibility between (salt-free) ion exchange chromatography and reversed phase chromatography–mass spectrometry allowed us to downscale the dimensions of the RP analytical column down to 25 μm i.d. for an additional 2- to 3-fold improvement in performance compared to current technology. The achieved levels of sensitivity, orthogonality, and compatibility demonstrates the potential of salt-free ACE MudPIT for the ultrasensitive, multidimensional analysis of very modest amounts of sample material.

Keywords

Citation

Mommen, G P M, Meiring, H D, Heck, A J R & de Jong, A P J M 2013, 'Mixed-Bed Ion Exchange Chromatography Employing a Salt-Free pH Gradient for Improved Sensitivity and Compatibility in MudPIT', Analytical Chemistry, vol. 85, pp. 6608-6616. https://doi.org/10.1021/ac400995e