Dosimetric impact of intrafraction motion under abdominal compression during MR-guided SBRT for (Peri-) pancreatic tumors

Publication date

2022-09-21

Authors

Grimbergen, Guus
Eijkelenkamp, Hidde
Heerkens, Hanne D.
Raaymakers, Bas WORCID 0000-0002-8036-6808ISNI 0000000392005337
Intven, M. P.W.ORCID 0000-0002-5068-5517ISNI 0000000393019546
Meijer, Gert J.ORCID 0000-0001-7275-319XISNI 0000000389724736

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Objective. Intrafraction motion is a major concern for the safety and effectiveness of high dose stereotactic body radiotherapy (SBRT) in the upper abdomen. In this study, the impact of the intrafraction motion on the delivered dose was assessed in a patient group that underwent MR-guided radiotherapy for upper abdominal malignancies with an abdominal corset. Approach. Fast online 2D cine MRI was used to extract tumor motion during beam-on time. These tumor motion profiles were combined with linac log files to reconstruct the delivered dose in 89 fractions of MR-guided SBRT in twenty patients. Aside the measured tumor motion, motion profiles were also simulated for a wide range of respiratory amplitudes and drifts, and their subsequent dosimetric impact was calculated in every fraction. Main results. The average (SD) D 99%of the gross tumor volume (GTV), relative to the planned D 99%, was 0.98 (0.03). The average (SD) relative D 0.5 cc of the duodenum, small bowel and stomach was 0.99 (0.03), 1.00 (0.03), and 0.97 (0.05), respectively. No correlation of respiratory amplitude with dosimetric impact was observed. Fractions with larger baseline drifts generally led to a larger uncertainty of dosimetric impact on the GTV and organs at risk (OAR). The simulations yielded that the delivered dose is highly dependent on the direction of on baseline drift. Especially in anatomies where the OARs are closely abutting the GTV, even modest LRor APdrifts can lead to substantial deviations from the planned dose. Significance. The vast majority of the fractions was only modestly impacted by intrafraction motion, increasing our confidence that MR-guided SBRT with abdominal compression can be safely executed for patients with abdominal tumors, without the use of gating or tracking strategies.

Keywords

Abdomen, Abdominal Neoplasms/diagnostic imaging, Humans, MR-guided radiotherapy, Motion, Pancreatic Neoplasms/diagnostic imaging, Radiometry, Radiosurgery/adverse effects, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted/methods, Radiotherapy, Intensity-Modulated/methods, abdominal compression, dose accumulation, intrafraction motion, pancreatic cancer, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Grimbergen, G, Eijkelenkamp, H, Heerkens, H D, Raaymakers, B W, Intven, M P W & Meijer, G J 2022, 'Dosimetric impact of intrafraction motion under abdominal compression during MR-guided SBRT for (Peri-) pancreatic tumors', Physics in medicine and biology, vol. 67, no. 18, 185016, pp. 1-9. https://doi.org/10.1088/1361-6560/ac8ddd