Homogeneous B1 + for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array

Publication date

2019-02

Authors

Krikken, Erwin
Steensma, Bart R
Voogt, Ingmar J.
Luijten, Peter R.ORCID 0000-0002-8040-8449ISNI 0000000397136870
Klomp, Dennis W.J.ORCID 0000-0002-5884-5386ISNI 0000000396514008
Raaijmakers, AJEISNI 0000000396109782
Wijnen, JannieORCID 0000-0003-2352-3667ISNI 0000000387155509

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

To explore the use of five meandering dipole antennas in a multi-transmit setup, combined with a high density receive array for breast imaging at 7 T for improved penetration depth and more homogeneous B1 field. Five meandering dipole antennas and 30 receiver loops were positioned on two cups around the breasts. Finite difference time domain simulations were performed to evaluate RF safety limits of the transmit setup. Scattering parameters of the transmit setup and coupling between the antennas and the detuned loops were measured. In vivo parallel imaging performance was investigated for various acceleration factors. After RF shimming, a B1 map, a T1-weighted image, and a T2-weighted image were acquired to assess B1 efficiency, uniformity in contrast weighting, and imaging performance in clinical applications. The maximum achievable local SAR10g value was 7.0 W/kg for 5 × 1 W accepted power. The dipoles were tuned and matched to a maximum reflection of −11.8 dB, and a maximum inter-element coupling of −14.2 dB. The maximum coupling between the antennas and the receive loops was −18.2 dB and the mean noise correlation for the 30 receive loops 7.83 ± 8.69%. In vivo measurements showed an increased field of view, which reached to the axilla, and a high transmit efficiency. This coil enabled the acquisition of T1-weighted images with a high spatial resolution of 0.7 mm3 isotropic and T2-weighted spin echo images with uniformly weighted contrast.

Keywords

Breast/diagnostic imaging, Computer Simulation, Female, Humans, Magnetic Resonance Imaging, Journal Article, Research Support, Non-U.S. Gov't

Citation

Krikken, E, Steensma, B R, Voogt, I J, Luijten, P R, Klomp, D W J, Raaijmakers, A J E & Wijnen, J P 2019, 'Homogeneous B 1  + for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array', NMR in Biomedicine, vol. 32, no. 2, e4039, pp. e4039. https://doi.org/10.1002/nbm.4039