Improved neonatal brain MRI segmentation by interpolation of motion corrupted slices

Publication date

2022-05-01

Authors

Verschuur, Anouk SORCID 0000-0001-8737-7078
Boswinkel, Vivian
Tax, Chantal M W
van Osch, Jochen A C
Nijholt, Ingrid
Slump, Cornelis H
de Vries, Linda S.ISNI 0000000117704571
van Wezel-Meijler, Gerda
Leemans, AlexanderORCID 0000-0002-9306-6126ISNI 0000000394149633
Boomsma, Martijn F

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc

Abstract

BACKGROUND AND PURPOSE: To apply and evaluate an intensity-based interpolation technique, enabling segmentation of motion-affected neonatal brain MRI. METHODS: Moderate-late preterm infants were enrolled in a prospective cohort study (Brain Imaging in Moderate-late Preterm infants "BIMP-study") between August 2017 and November 2019. T2-weighted MRI was performed around term equivalent age on a 3T MRI. Scans without motion (n = 27 [24%], control group) and with moderate-severe motion (n = 33 [29%]) were included. Motion-affected slices were re-estimated using intensity-based shape-preserving cubic spline interpolation, and automatically segmented in eight structures. Quality of interpolation and segmentation was visually assessed for errors after interpolation. Reliability was tested using interpolated control group scans (18/54 axial slices). Structural similarity index (SSIM) was used to compare T2-weighted scans, and Sørensen-Dice was used to compare segmentation before and after interpolation. Finally, volumes of brain structures of the control group were used assessing sensitivity (absolute mean fraction difference) and bias (confidence interval of mean difference). RESULTS: Visually, segmentation of 25 scans (22%) with motion artifacts improved with interpolation, while segmentation of eight scans (7%) with adjacent motion-affected slices did not improve. Average SSIM was .895 and Sørensen-Dice coefficients ranged between .87 and .97. Absolute mean fraction difference was ≤0.17 for less than or equal to five interpolated slices. Confidence intervals revealed a small bias for cortical gray matter (0.14-3.07 cm3 ), cerebrospinal fluid (0.39-1.65 cm3 ), deep gray matter (0.74-1.01 cm3 ), and brainstem volumes (0.07-0.28 cm3 ) and a negative bias in white matter volumes (-4.47 to -1.65 cm3 ). CONCLUSION: According to qualitative and quantitative assessment, intensity-based interpolation reduced the percentage of discarded scans from 29% to 7%.

Keywords

interpolation, motion artifacts, MRI, neonatal, segmentation, Clinical Neurology, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Verschuur, A S, Boswinkel, V, Tax, C M W, van Osch, J A C, Nijholt, I M, Slump, C H, de Vries, L S, van Wezel-Meijler, G, Leemans, A & Boomsma, M F 2022, 'Improved neonatal brain MRI segmentation by interpolation of motion corrupted slices', Journal of Neuroimaging, vol. 32, no. 3, pp. 480-492. https://doi.org/10.1111/jon.12985