Quantitative assessment of the removal of indicator bacteria in full-scale treatment plants
Publication date
2004
Authors
Hijnen, W.A.M.
Medema, Gerriet Jan
Kooij, D. van der
Editors
Advisors
Supervisors
DOI
Document Type
Article
Metadata
Show full item recordCollections
License
Abstract
The elimination of thermotolerant coliforms (Coli44) and spores of sulphite-reducing clostridia
(SSRC) in full-scale water treatment was determined by large volume sampling. The objective was to
determine the elimination capacity of full-scale treatment processes for micro-organisms, both vegetative
bacteria and bacterial spores. In two short-periods in winter and summer, information was collected about
the elimination of Coli44 and SSRC by the overall treatment, the contribution of the unit processes and the
variability in elimination. Coli44 concentrations in the source waters were reduced by 3.2 to 6.3 log to an
average concentration sufficiently low to achieve more than 99% compliance with the drinking water
standard. The elimination of SSRC was lower (1.4 to 4.2) and SSRC were observed occasionally (>1%) in
finished water by the routine weekly sampling of 100 ml samples. The study also yielded much information
about the elimination efficacy of unit processes at the different locations, which enables process optimization
and improved process control. Moreover, it is demonstrated that this quantitative information on removal of
indicator bacteria by full-scale treatment systems can be used as input for quantitative microbial risk
assessment. Further research will be focussed on comparative studies on the removal of faecal indicators
and pathogens by unit processes and the improvement of the enumeration methods of pathogens in the
source water (recovery efficiencies, specificity).
Keywords
Elimination capacity, full-scale processes, indicator bacteria, large volume sampling, process optimisation, quantitative microbial risk assessment