Advanced image-supported lead placement in cardiac resynchronisation therapy: protocol for the multicentre, randomised controlled ADVISE trial and early economic evaluation

Publication date

2021-10-25

Authors

Wouters, Philippe C
van Lieshout, Chris
van Dijk, Vincent F
Delnoy, Peter-Paul Hm
Doevendans, PieterISNI 0000000110574516
Cramer, Maarten JISNI 0000000390984527
Frederix, Geert
van Slochteren, Frebus JORCID 0000-0003-2657-7409
Meine, MathiasORCID 0000-0002-1102-2155ISNI 0000000369243476

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc

Abstract

INTRODUCTION: Achieving optimal placement of the left ventricular (LV) lead in cardiac resynchronisation therapy (CRT) is a prerequisite in order to achieve maximum clinical benefit, and is likely to help avoid non-response. Pacing outside scar tissue and targeting late activated segments may improve outcome. The present study will be the first randomised controlled trial to compare the efficacy of real-time image-guided LV lead delivery to conventional CRT implantation. In addition, to estimate the cost-effectiveness of targeted lead implantation, an early decision analytic model was developed, and described here. METHODS AND ANALYSIS: A multicentre, interventional, randomised, controlled trial will be conducted in a total of 130 patients with a class I or IIa indication for CRT implantation. Patients will be stratified to ischaemic heart failure aetiology and 1:1 randomised to either empirical lead placement or live image-guided lead placement. Ultimate lead location and echocardiographic assessment will be performed by core laboratories, blinded to treatment allocation and patient information. Late gadolinium enhancement cardiac magnetic resonance imaging (CMR) and CINE-CMR with feature-tracking postprocessing software will be used to semi-automatically determine myocardial scar and late mechanical activation. The subsequent treatment file with optimal LV-lead positions will be fused with the fluoroscopy, resulting in live target-visualisation during the procedure. The primary endpoint is the difference in percentage of successfully targeted LV-lead location. Secondary endpoints are relative percentage reduction in indexed LV end-systolic volume, a hierarchical clinical endpoint, and quality of life. The early analytic model was developed using a Markov-model, consisting of seven mutually exclusive health states. ETHICS AND DISSEMINATION: The protocol was approved by the Medical Research Ethics Committee Utrecht (NL73416.041.20). All participants are required to provide written informed consent. Results will be submitted to peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT05053568; Trial NL8666.

Keywords

Cardiovascular imaging, Heart failure, MRI, Pacing & electrophysiology, General Medicine

Citation

Wouters, P C, van Lieshout, C, van Dijk, V F, Delnoy, P-P H, Doevendans, P A, Cramer, M J, Frederix, G W, van Slochteren, F J & Meine, M 2021, 'Advanced image-supported lead placement in cardiac resynchronisation therapy : protocol for the multicentre, randomised controlled ADVISE trial and early economic evaluation', BMJ Open, vol. 11, no. 10, e054115, pp. 1-8. https://doi.org/10.1136/bmjopen-2021-054115