Right Ventricular Functional Abnormalities in Arrhythmogenic Cardiomyopathy: Association With Life-Threatening Ventricular Arrhythmias

Publication date

2021-05

Authors

Kirkels, F P
Lie, Øyvind H.
Cramer, Maarten JISNI 0000000390984527
Chivulescu, Monica
Rootwelt-Norberg, Christine
Asselbergs, Folkert WORCID 0000-0002-1692-8669ISNI 0000000391548591
Teske, Arco J.ISNI 0000000396645403
Haugaa, Kristina H.

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc_nd

Abstract

Objectives: This study aimed to perform an external validation of the value of right ventricular (RV) deformation patterns and RV mechanical dispersion in patients with arrhythmogenic cardiomyopathy (AC). Secondly, this study assessed the association of these parameters with life-threatening ventricular arrhythmia (VA). Background: Subtle RV dysfunction assessed by echocardiographic deformation imaging is valuable in AC diagnosis and risk prediction. Two different methods have emerged, the RV deformation pattern recognition and RV mechanical dispersion, but these have neither been externally validated nor compared. Methods: We analyzed AC probands and mutation-positive family members, matched from 2 large European referral centers. We performed speckle tracking echocardiography, whereby we classified the subtricuspid deformation patterns from normal to abnormal and assessed RV mechanical dispersion from 6 segments. We defined VA as sustained ventricular tachycardia, appropriate implantable cardioverter-defibrillator therapy, or aborted cardiac arrest. Results: We included 160 subjects, 80 from each center (43% proband, 55% women, age 41 ± 17 years). VA had occurred in 47 (29%) subjects. In both cohorts, patients with a history of VA showed abnormal deformation patterns (96% and 100%) and had greater RV mechanical dispersion (53 ± 30 ms vs. 30 ± 21 ms; p < 0.001 for the total cohort). Both parameters were independently associated to VA (adjusted odds ratio: 2.71 [95% confidence interval: 1.47 to 5.00] per class step-up, and 1.26 [95% confidence interval: 1.07 to 1.49]/10 ms, respectively). The association with VA significantly improved when adding RV mechanical dispersion to pattern recognition (net reclassification improvement 0.42; p = 0.02 and integrated diagnostic improvement 0.06; p = 0.01). Conclusions: We externally validated 2 RV dysfunction parameters in AC. Adding RV mechanical dispersion to RV deformation patterns significantly improved the association with life-threatening VA, indicating incremental value.

Keywords

arrhythmogenic cardiomyopathy, ARVC, deformation imaging, strain, ventricular arrhythmia, Radiology Nuclear Medicine and imaging, Cardiology and Cardiovascular Medicine

Citation

Kirkels, F P, Lie, Ø H, Cramer, M J, Chivulescu, M, Rootwelt-Norberg, C, Asselbergs, F W, Teske, A J & Haugaa, K H 2021, 'Right Ventricular Functional Abnormalities in Arrhythmogenic Cardiomyopathy : Association With Life-Threatening Ventricular Arrhythmias', JACC: Cardiovascular Imaging, vol. 14, no. 5, pp. 900-910. https://doi.org/10.1016/j.jcmg.2020.12.028