Prospective study of endoscopic focal cryoballoon ablation for esophageal squamous cell neoplasia in China
Publication date
2019-08
Authors
Ke, Yan
van Munster, Sanne N
Xue, Liyan
He, Shun
Zhang, Yueming
Dou, Lizhou
Liu, Yong
Liu, Xudong
Liu, Yumeng
Li, Wei
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
Background and Aims: Esophageal squamous cell neoplasia (ESCN) has a significant risk for progression to cancer. Current treatment options, endoscopic mucosal resection (EMR) or submucosal dissection (ESD), have their limitations. The cryoballoon focal ablation system (CbFAS) is a novel endoscopic ablation therapy device. We aimed to assess the safety, tolerability, and efficacy of CbFAS for eradication of ESCN. Methods: In this single-center prospective trial in China, patients with 1 flat unstained lesion (USL) on Lugol chromoendoscopy that contained moderate- or high-grade intraepithelial neoplasia (MGIN or HGIN, respectively) were enrolled. CbFAS was performed using side-by-side applications of 10 seconds, treatment was repeated at 3-month intervals until a complete response (CR) was established. The response at 12 months was the primary trial endpoint. Safety phone calls were performed at 2, 7, and 30 days after the initial CbFAS. Results: We enrolled 80 patients (59 MGIN, 21 HGIN) with a median USL length of 3 cm (interquartile range [IQR], 3-4). Seventy-nine received treatment, with a median of 5 side-by-side applications (IQR, 4-7) per patient over a median of 8 minutes (IQR, 5-10). After a single treatment, 70 of 78 patients (90%) exhibited CR, and 1 was lost to follow-up. The other 8 with persisting USLs were retreated, and all achieved CR after this second treatment. At 12 months after the initial CbFAS, 76 of 78 patients (97%) exhibited CR and 2 (3%) had recurrent MGIN. No strictures or serious adverse events occurred. Four patients developed self-limiting mucosal lacerations on balloon inflation. The postprocedure median pain score was 1 of 10 (IQR, 0-2) at day 2 and 0 (0-0) at days 7 and 30. Conclusions: The results suggest that the CbFAS is safe, well tolerated, and effective in inducing endoscopic and histologic remission in patients with ESCN of limited size. (Clinical trial registration number: NCT02605759.)
Keywords
Taverne, Radiology Nuclear Medicine and imaging, Gastroenterology
Citation
Ke, Y, van Munster, S N, Xue, L, He, S, Zhang, Y, Dou, L, Liu, Y, Liu, X, Liu, Y, Li, W, Lv, N, Dawsey, S M, Weusten, B L A M, Bergman, J J G H M & Wang, G 2019, 'Prospective study of endoscopic focal cryoballoon ablation for esophageal squamous cell neoplasia in China', Gastrointestinal Endoscopy, vol. 90, no. 2, pp. 204-212. https://doi.org/10.1016/j.gie.2019.03.017