Normal imaging findings after aortic valve implantation on 18F-Fluorodeoxyglucose positron emission tomography with computed tomography

Publication date

2021-10

Authors

Wahadat, Ali R
Tanis, Wilco
Scholtens, Asbjørn M
Bekker, Margreet
Graven, Laura H
Swart, Laurens E
den Harder, Annemarie M.
Lam, MarnixORCID 0000-0002-4902-9790
de Heer, LindaISNI 0000000390404246
Roos-Hesselink, Jolien W

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

BACKGROUND: To determine the normal perivalvular 18F-Fluorodeoxyglucose (18F-FDG) uptake on positron emission tomography (PET) with computed tomography (CT) within one year after aortic prosthetic heart valve (PHV) implantation. METHODS: Patients with uncomplicated aortic PHV implantation were prospectively included and underwent 18F-FDG PET/CT at either 5 (± 1) weeks (group 1), 12 (± 2) weeks (group 2) or 52 (± 8) weeks (group 3) after implantation. 18F-FDG uptake around the PHV was scored qualitatively (none/low/intermediate/high) and quantitatively by measuring the maximum Standardized Uptake Value (SUVmax) and target to background ratio (SUVratio). RESULTS: In total, 37 patients (group 1: n = 12, group 2: n = 12, group 3: n = 13) (mean age 66 ± 8 years) were prospectively included. Perivalvular 18F-FDG uptake was low (8/12 (67%)) and intermediate (4/12 (33%)) in group 1, low (7/12 (58%)) and intermediate (5/12 (42%)) in group 2, and low (8/13 (62%)) and intermediate (5/13 (38%)) in group 3 (P = 0.91). SUVmax was 4.1 ± 0.7, 4.6 ± 0.9 and 3.8 ± 0.7 (mean ± SD, P = 0.08), and SUVratio was 2.0 [1.9 to 2.2], 2.0 [1.8 to 2.6], and 1.9 [1.7 to 2.0] (median [IQR], P = 0.81) for groups 1, 2, and 3, respectively. CONCLUSION: Non-infected aortic PHV have similar low to intermediate perivalvular 18F-FDG uptake with similar SUVmax and SUVratio at 5, 12, and 52 weeks after implantation.

Keywords

Image interpretation, Infection, Inflammation, PET, Valvular heart disease, Cardiology and Cardiovascular Medicine, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Wahadat, A R, Tanis, W, Scholtens, A M, Bekker, M, Graven, L H, Swart, L E, den Harder, A M, Lam, M G E H, de Heer, L M, Roos-Hesselink, J W & Budde, R P J 2021, 'Normal imaging findings after aortic valve implantation on 18 F-Fluorodeoxyglucose positron emission tomography with computed tomography', Journal of Nuclear Cardiology, vol. 28, no. 5, pp. 2258-2268. https://doi.org/10.1007/s12350-019-02025-y