3D printed and punched porous surfaces of a non-resorbable, biphasic implant for the repair of osteochondral lesions improves repair tissue adherence and ingrowth

Publication date

2023-11

Authors

Fugazzola, Maria C.ISNI 0000000069332565
Golafshan, Nasim
van Aken, Joris A.
Plomp, Saskia G MISNI 0000000492915434
de Grauw, JannyISNI 0000000397213987
van Buul, Ward
Hermsen, Gied
Weinans, Harrie
Castilho, Miguel
van Weeren, P. RenéORCID 0000-0002-6654-1817ISNI 0000000390951215

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

taverne

Abstract

Summary: The objective of this study was to evaluate a non-resorbable implant for the focal repair of osteochondral defects. Enhanced adherence of repair cartilage overgrowing the implants was the secondary goal and was tested by introducing porosities on the articular surface of the implant. This study evaluated four versions of the construct composed of a polycarbonate-urethane-urea biomaterial (elastomer) and a bone anchor. In order to induce porosities on the surface of the implant, either vertical holes were punched into it, or the chondral component was 3D-printed onto the implant. Fabrication, biomechanical characterization and cell infiltration of the implant were evaluated in-vitro. Subsequently the implants were tested in an in-vivo study in four Shetland ponies for 5 weeks. Enhanced porosity was successfully obtained for all implants. The 3D-printing of the elastomeric material produced pore diameters of 775μm and 690μm whilst the micro-punched pores had a diameter of 319μm. The elastic modulus of the elastomer decreased with the introduction of porosity but stayed above values of native cartilage in all versions of the implant. Clinically the implant was well tolerated. The over-growing repair tissue was mostly flush with surrounding cartilage and attached to the elastomer through ingrowth of the tissue into the pores. Overall the tested implants all showed good mechanical performance in vitro and subjectively also in vivo. The repair cartilage was solidly attached to the porous surface of the implant. The printing approach potentially enables fine-tuning of the biomechanical properties of the implant depending on the specific requirements for a given location.

Keywords

3D printing, cartilage, horse model, implant, Joint, osteoarthritis, Taverne, Equine

Citation

Fugazzola, M C, Golafshan, N, van Aken, J A, Plomp, S, De Grauw, J, van Buul, W, Hermsen, G, Weinans, H, Castilho, M, van Weeren, R & Malda, J 2023, '3D printed and punched porous surfaces of a non-resorbable, biphasic implant for the repair of osteochondral lesions improves repair tissue adherence and ingrowth', Pferdeheilkunde, vol. 39, no. 6, pp. 504-514. https://doi.org/10.21836/PEM20230601