Quantification of the effect of instrumentation error in objective gait assessment in the horse on hindlimb symmetry parameters

Publication date

2018-05-01

Authors

Serra Braganca, FilipeISNI 0000000492921201
Rhodin, Marie
Wiestner, T.
Hernlund, ElinISNI 0000000506610704
Pfau, Thilo
van Weeren, RenéORCID 0000-0002-6654-1817ISNI 0000000390951215
Weishaupt, M.A.

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

Abstract

Background Objective gait analysis is becoming more popular as a tool assisting veterinarians during the clinical lameness exam. At present, there is only limited information on the effect of misplacement of markers/motion-sensors. Objectives To investigate and describe the effect of marker misplacement on commonly calculated pelvic symmetry parameters. Study design Experimental study. Methods Each horse was equipped with custom-made devices consisting of several reflective markers arranged in a predefined manner with a reference marker correctly positioned regarding the anatomical landmark and several misplaced markers along the sagittal and transverse planes. Linear regression analysis was used to estimate the effect of marker misplacement. Results For the tubera sacrale, each cm of left/right misplacement led to a difference in minimum position of the pelvis (PDmin) of ±1.67 mm (95% CI 1.54–1.8 mm) (P<0.001); maximum position of the pelvis (PDmax) was affected by ±0.2 mm (95% CI 0.071–0.33 mm) (P = 0.003). With respect to cranial/caudal misplacement, each cm of misplacement resulted in a PDmin difference of ±0.04 mm (95% CI −0.09 to 0.16 mm) (P = 0.56) and a PDmax difference of ±0.008 mm (95% CI −0.13 to 0.12 mm) (P = 0.9). For the tubera coxae, each cm of vertical misplacement led to a difference in the displacement amplitude between left and right tubera coxae (Hip-Hike_Diff) of ±1.56 mm (95% CI 1.35–1.77 mm) (P<0.001); for the cranial/caudal misplacement, this was ±0.82 mm (95% CI 0.66–0.97 mm) (P<0.001). Main limitations Only three horses were used in this experiment and the study design did not permit to determine the influence of marker misplacement on the evaluation of different degrees of lameness. Conclusions Marker misplacement significantly affects calculated symmetry parameters of the pelvis. The observed errors are overall small but significant. In cases of mildly asymmetrical horses, this error might influence the decision-making process whereas in more severe asymmetries, the influence of the error effect may become less significant.

Keywords

horse, gait analysis, lameness, symmetry, objective, marker placement

Citation

Serra Braganca, F M, Rhodin, M, Wiestner, T, Hernlund, E L, Pfau, T, van Weeren, P R & Weishaupt, M A 2018, 'Quantification of the effect of instrumentation error in objective gait assessment in the horse on hindlimb symmetry parameters', Equine Veterinary Journal, vol. 50, no. 3, pp. 370-376. https://doi.org/10.1111/evj.12766