A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections: a prospective cohort study
Files
Publication date
2015-01
Authors
Walter, Daisy
Will, Uwe
Sanchez-Yague, Andres
Brenke, Dirk
Hampe, Jochen
Wollny, Helge
López-Jamar, Jose Miguel Esteban
Jechart, Gertrud
Vilmann, Peter
Gornals, Joan B
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the efficacy and safety of this stent in a large cohort. PATIENTS AND METHODS: Patients with a PFC undergoing EUS-guided drainage with this novel stent were prospectively enrolled in this multicenter cohort study. RESULTS: There were 61 patients: 46 patients (75 %) with walled-off necrosis (WON) and 15 (25 %) with a pancreatic pseudocyst. Stent placement was technically successful in 60 patients (98 %, 95 %CI 95 % - 100 %). Clinical success, defined as resolution of clinical symptoms in combination with a decrease in the PFC size to ≤ 2 cm on imaging, was achieved in 93 % of patients with a pancreatic pseudocyst (95 %CI 77 % - 100 %) and in 81 % of patients with WON (95 %CI 69 % - 94 %). Treatment failure occurred in nine patients (16 %, 95 %CI 6 % - 26 %), including four patients who required surgical intervention. Stent removal was performed in 82 % of patients after a median of 32 days (range 2 - 178) and was rated as easy in all but one patient. In 10 patients, endoscopic stent removal was not performed because of stent migration (n = 3), stent dislodgement during necrosectomy (n = 3), stent removal during surgery (n = 2), or refusal by the patient (n = 2). In total, five major complications were reported (9 %, 95 %CI 2 % - 16 %), including PFC infection (n = 4) and perforation (n = 1). CONCLUSION: EUS-guided drainage using this novel stent is feasible and the clinical results obtained are promising with a low major complication rate.
Keywords
Adult, Aged, Drainage, Endosonography, Female, Follow-Up Studies, Humans, Logistic Models, Male, Middle Aged, Pancreatic Pseudocyst, Pancreatitis, Acute Necrotizing, Prospective Studies, Stents, Treatment Outcome, Ultrasonography, Interventional, Taverne, Clinical Trial, Journal Article, Multicenter Study
Citation
Walter, D, Will, U, Sanchez-Yague, A, Brenke, D, Hampe, J, Wollny, H, López-Jamar, J M E, Jechart, G, Vilmann, P, Gornals, J B, Ullrich, S, Fähndrich, M, de Tejada, A H, Junquera, F, Gonzalez-Huix, F, Siersema, P D & Vleggaar, FP 2015, 'A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections : a prospective cohort study', Endoscopy, vol. 47, no. 1, pp. 63-7. https://doi.org/10.1055/s-0034-1378113