Mammographic density assessed on paired raw and processed digital images and on paired screen-film and digital images across three mammography systems
Files
Publication date
2016-12-19
Authors
Burton, Anya
Byrnes, Graham
Stone, Jennifer
Tamimi, Rulla M
Heine, John
Vachon, Celine
Ozmen, Vahit
Pereira, Ana
Garmendia, Maria Luisa
Scott, Christopher
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
Abstract
BACKGROUND: Inter-women and intra-women comparisons of mammographic density (MD) are needed in research, clinical and screening applications; however, MD measurements are influenced by mammography modality (screen film/digital) and digital image format (raw/processed). We aimed to examine differences in MD assessed on these image types. METHODS: We obtained 1294 pairs of images saved in both raw and processed formats from Hologic and General Electric (GE) direct digital systems and a Fuji computed radiography (CR) system, and 128 screen-film and processed CR-digital pairs from consecutive screening rounds. Four readers performed Cumulus-based MD measurements (n = 3441), with each image pair read by the same reader. Multi-level models of square-root percent MD were fitted, with a random intercept for woman, to estimate processed-raw MD differences. RESULTS: Breast area did not differ in processed images compared with that in raw images, but the percent MD was higher, due to a larger dense area (median 28.5 and 25.4 cm(2) respectively, mean √dense area difference 0.44 cm (95% CI: 0.36, 0.52)). This difference in √dense area was significant for direct digital systems (Hologic 0.50 cm (95% CI: 0.39, 0.61), GE 0.56 cm (95% CI: 0.42, 0.69)) but not for Fuji CR (0.06 cm (95% CI: -0.10, 0.23)). Additionally, within each system, reader-specific differences varied in magnitude and direction (p < 0.001). Conversion equations revealed differences converged to zero with increasing dense area. MD differences between screen-film and processed digital on the subsequent screening round were consistent with expected time-related MD declines. CONCLUSIONS: MD was slightly higher when measured on processed than on raw direct digital mammograms. Comparisons of MD on these image formats should ideally control for this non-constant and reader-specific difference.
Keywords
Breast density, Image processing, Mammographic density assessment, Breast cancer, Methods, Journal Article
Citation
Burton, A, Byrnes, G, Stone, J, Tamimi, R M, Heine, J, Vachon, C, Ozmen, V, Pereira, A, Garmendia, M L, Scott, C, Hipwell, J H, Dickens, C, Schüz, J, Aribal, M E, Bertrand, K, Kwong, A, Giles, G G, Hopper, J, Pérez Gómez, B, Pollán, M, Teo, S-H, Mariapun, S, Taib, N A M, Lajous, M, Lopez-Riduara, R, Rice, M, Romieu, I, Flugelman, A A, Ursin, G, Qureshi, S, Ma, H, Lee, E, Sirous, R, Sirous, M, Lee, J W, Kim, J, Salem, D, Kamal, R, Hartman, M, Miao, H, Chia, K-S, Nagata, C, Vinayak, S, Ndumia, R, van Gils, C H, Wanders, J O P, Peplonska, B, Bukowska, A, Allen, S, Vinnicombe, S, Moss, S, Chiarelli, A M, Linton, L, Maskarinec, G, Yaffe, M J, Boyd, N F, Dos-Santos-Silva, I & McCormack, V A 2016, 'Mammographic density assessed on paired raw and processed digital images and on paired screen-film and digital images across three mammography systems', Breast Cancer Research, vol. 18, 18:130. https://doi.org/10.1186/s13058-016-0787-0