Systematic review and meta-analysis of the diagnostic accuracy of ductoscopy in patients with pathological nipple discharge

Publication date

2016-05-01

Authors

Waaijer, L.
Simons, Janine M
Borel Rinkes, InneORCID 0000-0003-2122-7207ISNI 0000000388761076
van Diest, Paul JORCID 0000-0003-0658-2745ISNI 000000004213151X
Verkooijen, Helena MORCID 0000-0001-9480-1623
Witkamp, Arjen JORCID 0000-0002-0313-8844ISNI 0000000387547115

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Background Invasive surgery remains the standard for diagnosis of pathological nipple discharge (PND). Only a minority of patients with nipple discharge and an unsuspicious finding on conventional breast imaging have cancer. Ductoscopy is a minimally invasive alternative for evaluation of PND. This systematic review and meta-analysis was designed to evaluate the diagnostic accuracy of ductoscopy in patients with PND.  Methods A systematic search of electronic databases for studies addressing ductoscopy in patients with PND was conducted. Two classification systems were assessed. For DSany, all visualized ductoscopic abnormalities were classified as positive, whereas for DSsusp, only suspicious findings were considered positive. After checking heterogeneity, pooled sensitivity and specificity of DSany and DSsusp were calculated.  Results The search yielded 4642 original citations, of which 20 studies were included in the review. Malignancy rates varied from 0 to 27 per cent. Twelve studies, including 1994 patients, were eligible for meta-analysis. Pooled sensitivity and specificity of DSany were 94 (95 per cent c.i. 88 to 97) per cent and 47 (44 to 49) per cent respectively. Pooled sensitivity and specificity of DSsusp were 50 (36 to 64) and 83 (81 to 86) per cent respectively. Heterogeneity between studies was moderate to large for sensitivity (DSany: I2 = 17·5 per cent; DSsusp: I2 = 37·9 per cent) and very large for specificity (DSany: I2 = 96·8 per cent; DSsusp: I2 = 92·6 per cent).  Conclusion Ductoscopy detects about 94 per cent of all underlying malignancies in patients with PND, but does not permit reliable discrimination between malignant and benign findings.

Keywords

Taverne, Surgery

Citation

Waaijer, L, Simons, J M, Borel Rinkes, I H M, Van Diest, P J, Verkooijen, H M & Witkamp, A J 2016, 'Systematic review and meta-analysis of the diagnostic accuracy of ductoscopy in patients with pathological nipple discharge', British Journal of Surgery, vol. 103, no. 6, pp. 632-643. https://doi.org/10.1002/bjs.10125