Three-dimensional rotational angiography in children with an aortic coarctation

Publication date

2016-09-22

Authors

Starmans, N L P
Krings, Gregor J
Molenschot, MirellaISNI 000000039390596X
van der Stelt, FemkeORCID 0000-0001-8585-7107
Breur, Johannes M P JISNI 0000000395622111

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

BACKGROUND: Children with aortic coarctations (CoA) are increasingly percutaneously treated. Good visualisation of the CoA is mandatory and can be obtained with three-dimensional rotational angiography (3DRA). This study aims to compare the diagnostic and therapeutic additional value of 3DRA with conventional biplane angiography (CA) in children with a CoA. METHODS: Patients undergoing percutaneous treatment of CoA with balloon angioplasty (BA) or stent between 2003 and 2015, were retrospectively reviewed on success rate, complications, radiation and technical settings. Diagnostic quality of CA and 3DRA and additional value of 3DRA were scored. RESULTS: In total, 134 patients underwent 183 catheterisations, 121 CA and 62 3DRA-guided. Median age was 0.52 years in the BA group and 11.19 years in the stent group. 3DRA was superior to CA in displaying the left ventricle (p = 0.008), ascending aorta (p < 0.001), aortic arch (p = 0.005) and coronary arteries (p < 0.001). In the BA group, 3DRA had a significantly higher success rate than CA (100.0 % versus 68.9 %, p = 0.016). All stent interventions were successful. Complication rates did not differ significantly. The median total dose area product did not significantly differ between CA and 3DRA in the BA (27.88 μGym(2)/kg versus 15.81 μGym(2)/kg, p = 0.275) or stent group (37.34 μGym(2)/kg versus 45.24 μGym(2)/kg, p = 0.090). 3DRA was of additional value in 96.8 % of the interventions. CONCLUSIONS: 3DRA is superior to CA in diagnostic quality and not associated with increased radiation exposure. It provides high additional value in guiding CoA related interventions.

Keywords

Angiography, Aortic coarctation, Congenital heart defects, Endovascular procedures, Paediatrics, Three-dimensional imaging, Journal Article

Citation

Starmans, N L P, Krings, G J, Molenschot, M M C, van der Stelt, F & Breur, J M P J 2016, 'Three-dimensional rotational angiography in children with an aortic coarctation', Netherlands Heart Journal, vol. 24, no. 11, pp. 666–674. https://doi.org/10.1007/s12471-016-0899-2