ALICE: A tool for automatic localization of intra-cranial electrodes for clinical and high-density grids

Publication date

2018-05-01

Authors

Branco, Mariana P.ORCID 0000-0002-7316-8846
Gaglianese, Anna
Glen, Daniel R.
Hermes, Dora
Saad, Ziad S.
Petridou, NataliaORCID 0000-0002-0783-0387ISNI 0000000392331001
Ramsey, Nick F.ORCID 0000-0002-7136-259XISNI 0000000399572879

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

Background: Electrocorticographic (ECoG) measurements require the accurate localization of implanted electrodes with respect to the subject's neuroanatomy. Electrode localization is particularly relevant to associate structure with function. Several procedures have attempted to solve this problem, namely by co-registering a post-operative computed tomography (CT) scan, with a pre-operative magnetic resonance imaging (MRI) anatomy scan. However, this type of procedure requires a manual and time-consuming detection and transcription of the electrode coordinates from the CT volume scan and restricts the extraction of smaller high-resolution ECoG grid electrodes due to the downsampling of the CT. New method: ALICE automatically detects electrodes on the post-operative high-resolution CT scan, visualizes them in a combined 2D and 3D volume space using AFNI and SUMA software and then projects the electrodes on the individual's cortical surface rendering. The pipeline integrates the multiple-step method into a user-friendly GUI in Matlab®, thus providing an easy, automated and standard tool for ECoG electrode localization. Results: ALICE was validated in 13 subjects implanted with clinical ECoG grids by comparing the calculated electrode center-of-mass coordinates with those computed using a commonly used method. Comparison with existing methods: A novel aspect of ALICE is the combined 2D-3D visualization of the electrodes on the CT scan and the option to also detect high-density ECoG grids. Feasibility was shown in 5 subjects and validated for 2 subjects. Conclusions: The ALICE pipeline provides a fast and accurate detection, discrimination and localization of ECoG electrodes spaced down to 4 mm apart.

Keywords

ALICE, Clinical grid, ECoG, Electrode localization, High-density grid, Integrated pipeline, Taverne, General Neuroscience

Citation

Branco, M P, Gaglianese, A, Glen, D R, Hermes, D, Saad, Z S, Petridou, N & Ramsey, N F 2018, 'ALICE : A tool for automatic localization of intra-cranial electrodes for clinical and high-density grids', Journal of Neuroscience Methods, vol. 301, pp. 43-51. https://doi.org/10.1016/j.jneumeth.2017.10.022