Abstract
BACKGROUND: To optimize and validate intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) compared with the apparent diffusion coefficient (ADC) for semi-automated analysis of breast lesions using a multi-reader setup. MATERIALS AND METHODS: Patients (n = 176) with breast lesions (≥1 cm) and known pathology were prospectively examined (1.5 Tesla) with DWI (b = 0, 50, 200, 500, 800, 1000 s/mm(2) ) between November 2008 and July 2014 and grouped into a training and test set. Three independent readers applied a semi-automated procedure for setting regions-of-interest for each lesion and recorded ADC and IVIM parameters: molecular diffusion (Dslow ), microperfusion (Dfast ), and the fraction of Dfast (ffast ). In the training set (24 lesions, 12 benign), a semi-automated method was optimized to yield maximum true negatives (TN) with minimal false negatives (FN): only the optimal fraction (Fo) of voxels in the lesions was used and optimal thresholds were determined. The optimal Fo and thresholds were then applied to a consecutive test set (139 lesions, 23 benign) to obtain specificity and sensitivity. RESULTS: In the training set, optimal thresholds were 1.44 × 10(-3) mm(2) /s (Dslow ), 18.55 × 10(-3) mm(2) /s (Dfast ), 0.247 (ffast ) and 2.00 × 10(-3) mm(2) /s (ADC) with Fo set to 0.61, 0.85, 1.0, and 1.0, respectively, this resulted in TN = 5 (IVIM) and TN = 1 (ADC), with FN = 0. In the test set, sensitivity and specificity among the readers were 90.5-93.1% and 43.5-52.2%, respectively, for IVIM, and 94.8-95.7% and 13.0-21.7% for ADC (P ≤ 0.0034) without inter-reader differences (P = 1.000). CONCLUSION: The presented semi-automated method for breast lesion evaluation is reader independent and yields significantly higher specificity for IVIM compared with the ADC.
Keywords
diffusion weighted MRI, breast, cancer, diagnostic techniques and procedures, Taverne, Journal Article
Citation
Dijkstra, H, Dorrius, M D, Wielema, M, Jaspers, K, Pijnappel, R M, Oudkerk, M & Sijens, P E 2016, 'Semi-automated quantitative intravoxel incoherent motion analysis and its implementation in breast diffusion-weighted imaging', Journal of Magnetic Resonance Imaging, vol. 43, no. 5, pp. 1122-1131. https://doi.org/10.1002/jmri.25086