Synthetic CT for single-fraction neoadjuvant partial breast irradiation on an MRI-linac

Publication date

2021-04-21

Authors

Groot Koerkamp, MaureenORCID 0000-0002-1976-5797
de Hond, Yvonne J M
Maspero, MatteoORCID 0000-0003-0347-3375
Kontaxis, Charis
Mandija, StefanoORCID 0000-0002-4612-5509
Vasmel, Jeanine E
Charaghvandi, Ramona K
Philippens, Marielle E PORCID 0000-0003-0205-3459ISNI 0000000387302804
van Asselen, BISNI 0000000391220676
van den Bongard, Desirée H J GISNI 0000000388003670

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

taverne

Abstract

A synthetic computed tomography (sCT) is required for daily plan optimization on an MRI-linac. Yet, only limited information is available on the accuracy of dose calculations on sCT for breast radiotherapy. This work aimed to 1) evaluate dosimetric accuracy of treatment plans for single-fraction neoadjuvant partial breast irradiation (PBI) on a 1.5T MRI-linac calculated on a) bulk-density sCT mimicking the current MRI-linac workflow and b) deep learning-generated sCT, and 2) investigate the number of bulk-density levels required. For ten breast cancer patients we created three bulk-density sCTs of increasing complexity from the planning-CT, using bulk-density for: 1) body, lungs, and GTV (sCTBD1); 2) volumes for sCTBD1plus chest wall and ipsilateral breast (sCTBD2); 3) volumes for sCTBD2plus ribs (sCTBD3); and a deep learning-generated sCT (sCTDL) from a 1.5T MRI in supine position. Single-fraction neoadjuvant PBI treatment plans for a 1.5T MRI-linac were optimized on each sCT and recalculated on the planning-CT. Image evaluation was performed by assessing mean absolute error (MAE) and mean error (ME) in Hounsfield Units (HU) between the sCTs and the planning-CT. Dosimetric evaluation was performed by assessing dose differences, gamma pass rates, and dose-volume histogram (DVH) differences. The following results were obtained (median across patients for sCTBD1/sCTBD2/sCTBD3/sCTDLrespectively): MAE inside the body contour was 106/104/104/75 HU and ME was 8/9/6/28 HU, mean dose difference in the PTVGTV was 0.15/0.00/0.00/-0.07 Gy, median gamma pass rate (2%/2mm, 10% dose threshold) was 98.9/98.9/98.7/99.4%, and differences in DVH parameters were well below 2% for all structures except for the skin in the sCTDL. Accurate dose calculations for single-fraction neoadjuvant PBI on an MRI-linac could be performed on both bulk-density and deep learning sCT, facilitating further implementation of MRI-guided radiotherapy for breast cancer. Balancing simplicity and accuracy, sCTBD2 showed the optimal number of bulk-density levels for a bulk-density approach.

Keywords

convolutional networks, MRI-linac, MRI-only radiotherapy, partial breast irradiation, pseudo-CT, Taverne, Radiological and Ultrasound Technology, Radiology Nuclear Medicine and imaging, Journal Article

Citation

Groot Koerkamp, M L, de Hond, Y J M, Maspero, M, Kontaxis, C, Mandija, S, Vasmel, J E, Charaghvandi, R K, Philippens, M E P, van Asselen, B, van den Bongard, H J G D, Hackett, S S & Houweling, A C 2021, 'Synthetic CT for single-fraction neoadjuvant partial breast irradiation on an MRI-linac', Physics in medicine and biology, vol. 66, no. 8, 085010. https://doi.org/10.1088/1361-6560/abf1ba