Automated prospective quality assurance of tumor segmentation and treatment planning in the hypo-FLAME 3.0 trial
Files
Publication date
2026-08
Authors
Surewaard, Joost
Bosschaert, Ruben
Beemster, Herbert
Schipaanboord, Bas
Dassen, Mathijs G.
Akdag, Osman
Doodeman, Barry
van den Bergh, Fons
Kunze-Busch, Martina
De Roover, Robin
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
Background and purpose: Iso-toxic focal boosting in prostate cancer radiotherapy is associated with improved disease-free survival but faces challenges due to tumor segmentation variability and unconventional treatment planning. The aim of this study was to develop an automated system of prospective quality assurance (QA) on tumor segmentation and treatment planning in a clinical trial setting and to implement it in the study arm of the multi-center hypo-FLAME 3.0 trial (NCT05705921) on iso-toxic focal boosting. Materials and methods: We developed an automated QA system to process data from participating centers, apply tumor segmentation evaluation models and plan evaluation models and generate reports for centralized review. Tumor segmentation was evaluated by a model generating tumor probability maps from MRI scans. Focal boost quality was evaluated with a model predicting achievable near-minimum dose for each tumor based on anatomical features. Results: The QA system was applied to 134 patients who participated in the study arm of the hypo-FLAME 3.0 trial between June 2023 and July 2025. They were recruited from 11 centers in the Netherlands and Belgium. Three and 10 out of 134 cases were recommended for resegmentation and replanning, respectively. We responded to external institutes within 12 business hours in 77% and 81% of the cases for the segmentation and the planning QA, respectively. Conclusion: We developed an automated system of prospective QA in a clinical trial setting and implemented it for all patients in the study arm of the phase III hypo-FLAME 3.0 trial.
Keywords
Clinical trial, Quality assurance, Taverne, Hematology, Oncology, Radiology Nuclear Medicine and imaging
Citation
Surewaard, J, Bosschaert, R, Beemster, H, Schipaanboord, B, Dassen, M G, Akdag, O, Doodeman, B, van den Bergh, F, Kunze-Busch, M, De Roover, R, Draulans, C, Haustermans, K, Schuring, D, Piersma, H, Pelgrims, A, Coelmont, A, Stoian, G, de Boer, H C J, Geens, K, Poeta, S, Janssen, T M, Pos, F J & van der Heide, U A 2026, 'Automated prospective quality assurance of tumor segmentation and treatment planning in the hypo-FLAME 3.0 trial', Radiotherapy and Oncology, vol. 221, 111608. https://doi.org/10.1016/j.radonc.2026.111608