Using individual patient data to adjust for indirectness did not successfully remove the bias in this case of comparative test accuracy

Publication date

2015-01-01

Authors

Wang, Junfeng
Bossuyt, Patrick
Geskus, Ronald
Zwinderman, Aeilko
Dólleman, Mdeleine
Broer, S. L.ISNI 0000000393442344
Broekmans, FrankISNI 0000000395585824
Mol, Ben Willem
Leeflang, Mariska

Editors

Advisors

Supervisors

Document Type

Article

Collections

License

Abstract

Objectives In comparative systematic reviews of diagnostic accuracy, inconsistencies between direct and indirect comparisons may lead to bias. We investigated whether using individual patient data (IPD) can adjust for this form of bias. Study Design and Setting We included IPD of 3 ovarian reserve tests from 32 studies. Inconsistency was defined as a statistically significant difference in relative accuracy or different comparative results between the direct and indirect evidence. We adjusted for the effect of threshold and reference standard, as well as for patient-specific variables. Results Anti-Müllerian hormone (AMH) and follicle stimulation hormone (FSH) differed significantly in sensitivity (-0.1563, P = 0.04). AMH and antral follicle count (AFC) differed significantly in sensitivity (0.1465, P < 0.01). AMH and AFC differed significantly in specificity (-0.0607, P = 0.02). The area under the curve (AUC) differed significantly between AFC and FSH (0.0948, P < 0.01) in the direct comparison but not (0.0678, P = 0.09) in the indirect comparison. The AUCs of AFC and AMH differed significantly (-0.0830, P < 0.01) in the indirect comparison but not (-0.0176, P = 0.29) in the direct comparison. These differences remained after adjusting for indirectness. Conclusion Estimates of comparative accuracy obtained through indirect comparisons are not always consistent with those obtained through direct comparisons. Using IPD to adjust for indirectness did not successfully remove the bias in this case study.

Keywords

Comparative meta-analysis, Diagnostic test accuracy, Generalized estimating equation, Individual patient data, Receiver operating characteristic, Sensitivity and specificity, Epidemiology, General Medicine, Comparative Study, Journal Article, Research Support, Non-U.S. Gov't

Citation

Wang, J, Bossuyt, P, Geskus, R, Zwinderman, A, Dólleman, M, Broer, S, Broekmans, F, Mol, B W & Leeflang, M 2015, 'Using individual patient data to adjust for indirectness did not successfully remove the bias in this case of comparative test accuracy', Journal of Clinical Epidemiology, vol. 68, no. 3, pp. 290-298. https://doi.org/10.1016/j.jclinepi.2014.10.005