Quantitative and qualitative flow cytometric analysis of nanosized cell-derived membrane vesicles

Publication date

2012-07

Authors

Nolte - t Hoen, EstherISNI 000000038915653X
van der Vlist, Els JISNI 0000000419438942
Aalberts, MarianISNI 0000000395734359
Mertens, Hendrik C H
Bosch, Berend JanISNI 0000000387346575
Bartelink, Willem
Mastrobattista, EnricoORCID 0000-0002-6745-2015ISNI 000000035187179X
van Gaal, E.V.B.ISNI 0000000392412354
Stoorvogel, WillemISNI 0000000396541970
Arkesteijn, Ger J A

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

Abstract

Nanosized cell-derived membrane vesicles are increasingly recognized as therapeutic vehicles and high-potential biomarkers for several diseases. Currently available methods allow bulk analysis of vesicles but are not suited for accurate quantification and fail to reveal phenotypic heterogeneity in membrane vesicle populations. For such analyses, single vesicle-based, multiparameter, high-throughput methods are needed. We developed a fluorescence-based, high-resolution flow cytometric method for quantitative and qualitative analysis of nanosized membrane vesicles. Proof of principle was obtained by single-particle analysis of virions and liposomes. Further validation was obtained by quantification of cell-derived nanosized membrane vesicles from cell cultures and body fluids. An important aspect was that the technology was extended to detect specific proteins on individual vesicles. This allowed identification of exosome subsets and phenotyping of individual exosomes produced by dendritic cells (DCs) undergoing different modes of activation. The described technology allows quantitative, multiparameter, and high-throughput analysis of a wide variety of nanosized particles and has broad applications. From the Clinical Editor: The authors developed a fluorescence-based, high-resolution flow cytometric method for quantitative and qualitative analysis of nanosized cell-derived membrane vesicles that are increasingly recognized both as therapeutic vehicles and high-potential biomarkers for several diseases. A high throughput, easily available, and sensitive detection method such as the one discussed here is a critically important prerequisite for further refinements of this technology.

Keywords

Biomarkers, Cellular membrane vesicles, Dendritic cells, Exosomes, Flow cytometry, Microvesicles, Nanovesicles, Coronacrisis-Taverne, Molecular Medicine, Bioengineering, Biomedical Engineering, General Materials Science, Medicine (miscellaneous), Pharmaceutical Science

Citation

Nolte - t Hoen, E N M, van der Vlist, E J, Aalberts, M, Mertens, H C H, Bosch, B J, Bartelink, W, Mastrobattista, E, van Gaal, E V B, Stoorvogel, W, Arkesteijn, G J A A & Wauben, M H M 2012, 'Quantitative and qualitative flow cytometric analysis of nanosized cell-derived membrane vesicles', Nanomedicine : nanotechnology, biology and medicine, vol. 8, no. 5, pp. 712-720. https://doi.org/10.1016/j.nano.2011.09.006