Echocardiography and cardiac resynchronisation therapy, friends or foes?

Publication date

2016-01

Authors

van Everdingen, Wouter MISNI 0000000464452962
Schipper, J G
van t Sant, Jetske
Misier, K. Ramdat
Meine, MathiasORCID 0000-0002-1102-2155ISNI 0000000369243476
Cramer, Maarten JISNI 0000000390984527

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

Keywords

3D echocardiography, Cardiac resynchronisation therapy, Deformation imaging, Dyssynchrony, Echocardiography, Follow-up, Interobserver variability, Optimisation, Response, Septal strain, Speckle tracking echocardiography, Volume, Cardiology and Cardiovascular Medicine, Journal Article

Citation

van Everdingen, W M, Schipper, J C, van t Sant, J, Misier, K R, Meine, M & Cramer, MJ 2016, 'Echocardiography and cardiac resynchronisation therapy, friends or foes?', Netherlands Heart Journal, vol. 24, no. 1, pp. 25-38. https://doi.org/10.1007/s12471-015-0769-3