A novel high-temperature combustion based system for stable isotope analysis of dissolved organic carbon in aqueous samples.: II optimization and assessment of analytical performance

Files

Access status: Embargo until 2050-01-01 , 53.pdf (1.41 MB)

Publication date

2014-12-15

Authors

Kirkels, Frédérique Marie Sophie AnneISNI 0000000492905674
Cerli, C.
Federherr, E.
Gao, J.
Kalbitz, K.

Editors

Advisors

Supervisors

Document Type

Article

License

Abstract

RATIONALE: Dissolved organic carbon (DOC) plays an important role in carbon cycling, making precise and routine measurement of delta C-13 values and DOC concentration highly desirable. A new promising system has been developed for this purpose. However, broad-scale application of this new technique requires an in-depth assessment of analytical performance, and this is described here. METHODS: A high-temperature combustion Total Organic Carbon analyzer was interfaced with continuous flow isotope ratio mass spectrometry (TOC/IRMS) for the simultaneous analysis of the bulk DOC concentration and delta C-13 signature. The analytical performance (precision, memory effects, linearity, volume/concentration effects, accuracy) was thoroughly evaluated, including realistic and challenging conditions such as low DOC concentrations and natural DOC. RESULTS: High precision (standard deviation, SD predominantly ≤0.15 ‰) and accuracy (R2 = 0.9997) were achieved for the δ13C analysis of a broad diversity of DOC solutions. Simultaneously, good results were obtained for the measurement of DOC concentration. Assessment of natural abundance and slightly 13C-enriched DOC, a wide range of concentrations (~0.2–150 mgC/L) and injection volumes (0.05–3 mL), demonstrated minor/negligible memory effects, good linearity and flexible usage. Finally, TOC/IRMS was successfully applied to determine low DOC concentrations (<2 mgC/L) and DOC from diverse terrestrial, freshwater and marine environments (SD ≤0.23 ‰). CONCLUSIONS: TOC/IRMS enables fast and reliable measurement of DOC concentrations and delta C-13 values in aqueous samples, without pre-concentration and freeze-drying. Further investigations should focus on complex, saline matrices and very low DOC concentrations, to achieve a potential lower limit of 0.2 mgC/L. Thus, TOC/IRMS will give DOC research in terrestrial and aquatic environments a huge impulse with high-resolution, routine delta C-13 analysis. Copyright (C) 2014 John Wiley & Sons, Ltd.

Keywords

RATIO MASS-SPECTROMETRY, WET CHEMICAL OXIDATION, HIGH ARCTIC GLACIER, INORGANIC CARBON, TERRESTRIAL ECOSYSTEMS, C-13 ANALYSIS, MATTER, SOIL, WATERS, ANALYZER, SDG 14 - Life Below Water, SDG 15 - Life on Land

Citation

Kirkels, F M S A, Cerli, C, Federherr, E, Gao, J & Kalbitz, K 2014, 'A novel high-temperature combustion based system for stable isotope analysis of dissolved organic carbon in aqueous samples. II optimization and assessment of analytical performance', Rapid Communications in Mass Spectrometry, vol. 28, no. 23, pp. 2574-2586. https://doi.org/10.1002/rcm.7053