Dynamic computed tomography of the pituitary gland using a single slice scanner in dogs with pituitary-dependent hypercortisolism

Publication date

2016-08

Authors

Del Magno, Sara
Grinwis, G.C.M.ISNI 0000000394959548
Voorhout, G.ISNI 0000000393129913
Meij, B.P.ORCID 0000-0002-0165-1169ISNI 0000000388662836

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

taverne

Abstract

Selective removal of the pituitary adenoma has not been advocated in dogs with pituitary-dependent hypercortisolism because the pituitary adenoma is usually not visualized on routine computed tomography (CT).Dynamic pituitary CT scanning is aimed at the detection of the pituitary flush and, indirectly, at the presence and position of the adenoma. The first aim of this retrospective study was to compare findings of a multiple slice dynamic scanning protocol with those of a single slice dynamic protocol using a single slice CT scanner. The second aim was to compare the CT findings with surgical findings, and surgical findings with histopathological findings.Computed tomography with single and multiple slice dynamic scanning protocols was performed in 86 dogs with pituitary-dependent hypercortisolism. Thirty dogs underwent transsphenoidal hypophysectomy and pituitary specimens were collected as tumor, normal, mixed and neurohypophyseal samples and processed for histology.The pituitary flush was not detected more frequent in multiple slice dynamic scanning series than in single slice dynamic scanning series. However, in non-enlarged pituitaries, the flush was seen significantly more frequently than in enlarged pituitaries.Prediction of the nature of the tissue during hypophysectomy by the surgeon was inconclusive.In conclusion, when using a single slice CT scanner, both single or multiple slice dynamic scanning protocols can be used for localization of the neurohypophyseal flush, and, indirectly, the adenoma. However, based on this study, the aim of surgery in dogs with pituitary-dependent hypercortisolism remains total adenohypophysectomy, and when the neurophypophysis is recognized, it may be left in situ.

Keywords

Dog, Dynamic computed tomography, Hypercortisolism, Hypophysectomy, Pituitary gland, Taverne, General Veterinary

Citation

Del Magno, S, Grinwis, G C M, Voorhout, G & Meij, B P 2016, 'Dynamic computed tomography of the pituitary gland using a single slice scanner in dogs with pituitary-dependent hypercortisolism', Research in Veterinary Science, vol. 107, pp. 42-49. https://doi.org/10.1016/j.rvsc.2016.04.005