Respiratory- and cardiac-triggered three-dimensional sheath inked rapid acquisition with refocused echoes imaging (SHINKEI) of the abdomen for magnetic resonance neurography of the celiac plexus

Publication date

2019-03-29

Authors

Ferrer, Cyril J.
Bos, CORCID 0000-0002-9246-3242ISNI 0000000388845122
Yoneyama, Masami
Obara, Makoto
Kok, Lisanne
van Leeuwen, Maarten SISNI 0000000396674175
Bleys, Ronald L A WISNI 0000000050357498
Moonen, C. T. W.ORCID 0000-0001-5593-3121ISNI 0000000038813649
Bartels, WilbertISNI 0000000388733745

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

Abstract

The visualisation of the celiac plexus using respiratory- and cardiac-triggered three-dimensional (3D) sheath inked rapid acquisition with refocused echoes imaging (SHINKEI) was evaluated. After ethical approval and written informed consent, eight volunteers (age 27 ± 5 years, mean ± standard deviation) were scanned at 1.5 and 3 T. Displacement of the celiac ganglia due to aortic pulsatility was studied on axial single-slice breath-hold balanced turbo field-echo cine sequences in five volunteers and found to be 3.0 ± 0.5 mm (left) and 3.1 ± 0.4 mm (right). Respiratory- and cardiac-triggered 3D SHINKEI images were compared to respiratory- and cardiac-triggered fat-suppressed 3D T2-weighted turbo spin-echo and respiratory-triggered 3D SHINKEI in all volunteers. Visibility of the celiac ganglia was rated by three radiologists as visible or non-visible. On 3D SHINKEI with double-triggering at 1.5 T, the left and right ganglia were seen by all observers in 7/8 and 8/8 volunteers, respectively. At 3 T, this was the case for 6/8 and 7/8 volunteers, respectively. The nerve-to-muscle signal ratio increased from 1.9 ± 0.5 on fat-suppressed 3D T2-weighted turbo spin-echo to 4.7 ± 0.8 with 3D SHINKEI. Anatomical validation was performed in a human cadaver. An expert in anatomy confirmed that the hyperintense structure visible on ex vivo 3D SHINKEI scans was the celiac plexus. In conclusion, double-triggering allowed visualisation of the celiac plexus using 3D SHINKEI at both 1.5 T and 3 T.

Keywords

Abdomen, Celiac plexus, Magnetic resonance imaging, Organ motion

Citation

Ferrer, C J, Bos, C, Yoneyama, M, Obara, M, Kok, L, van Leeuwen, M S, Bleys, R L A W, Moonen, C T W & Bartels, L W 2019, 'Respiratory- and cardiac-triggered three-dimensional sheath inked rapid acquisition with refocused echoes imaging (SHINKEI) of the abdomen for magnetic resonance neurography of the celiac plexus', European radiology experimental, vol. 3, no. 1, 14. https://doi.org/10.1186/s41747-019-0095-4