How can we reduce costs of solid-phase multiplex-bead assays used to determine anti-HLA antibodies?
Publication date
2016-09-01
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
Solid-phase multiplex-bead assays are widely used in transplantation to detect anti-human leukocyte antigen (HLA) antibodies. These assays enable high resolution detection of low levels of HLA antibodies. However, multiplex-bead assays are costly and yield variable measurements that limit the comparison of results between laboratories. In the context of a Dutch national Consortium study we aimed to determine the inter-assay and inter-machine variability of multiplex-bead assays, and we assessed how to reduce the assay reagents costs. Fifteen sera containing a variety of HLA antibodies were used yielding in total 7092 median fluorescence intensities (MFI) values. The inter-assay and inter-machine mean absolute relative differences (MARD) of the screening assay were 12% and 13%, respectively. The single antigen bead (SAB) inter-assay MARD was comparable, but showed a higher lot-to-lot variability. Reduction of screening assay reagents to 50% or 40% of manufacturers' recommendations resulted in MFI values comparable to 100% of the reagents, with an MARD of 12% or 14%, respectively. The MARD of the 50% and 40% SAB assay reagent reductions were 11% and 22%, respectively. From this study, we conclude that the reagents can be reliably reduced at least to 50% of manufacturers' recommendations with virtually no differences in HLA antibody assignments.
Keywords
human leukocyte antigen antibodies, luminex, single antigen, solid-phase multiplex-bead assays, Taverne, Genetics, Immunology, Immunology and Allergy, Journal Article
Citation
Kamburova, E G, Wisse, B W, Joosten, I, Allebes, W A, van der Meer, A, Hilbrands, L B, Baas, M C, Spierings, E, Hack, C E, van Reekum, F E, van Zuilen, A D, Verhaar, M, Bots, M L, Drop, A C A D, Plaisier, L, Seelen, M A J, Sanders, J S F, Hepkema, B G, Lambeck, A J, Bungener, L B, Roozendaal, C, Tilanus, M G J, Vanderlocht, J, Voorter, C E, Wieten, L, van Duijnhoven, E M, Gelens, M, Christiaans, M H L, van Ittersum, F J, Nurmohamed, A, Lardy, N M, Swelsen, W, van der Pant, K A, van der Weerd, N C, ten Berge, I J M, Bemelman, F J, Hoitsma, A, van der Boog, P J M, de Fijter, J W, Betjes, M G H, Heidt, S, Roelen, D L, Claas, F H & Otten, H G 2016, 'How can we reduce costs of solid-phase multiplex-bead assays used to determine anti-HLA antibodies?', HLA, vol. 88, no. 3, pp. 110-119. https://doi.org/10.1111/tan.12860