An ultra-sensitive liquid chromatography tandem mass spectrometry method for the simultaneous quantification of 2H6-alectinib and alectinib in human plasma to support a microtracer food-effect trial

Publication date

2025-03-01

Authors

van der Heijden, L. T.
Tibben, M. M.
Ali, M. I. Mohmaed
Aardenburg, L. G. J.
Steeghs, N.
Beijnen, JosISNI 0000000140305595
Rosing, H.
Huitema, A. D. R.

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

taverne

Abstract

A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of 2H6-alectinib and alectinib was developed and validated for the support of a pilot microtracer food-effect trial. The aim of the bioanalytical method was the simultaneous quantification of low 2H6-alectinib concentrations and high alectinib concentrations that are present in study samples, using a single sample pre-treatment and analysis method. Sample preparation consisted of liquid-liquid extraction with tert-butyl methyl ether (TBME). The final extract was injected on a C18 column (1.7 μm particles, 50 × 2.1 mm ID) with gradient elution. A triple quadruple mass spectrometer operating in positive method was used for detection and quantification. The validated concentration ranges were from 5 to 400 pg/mL for 2H6-alectinib and from 25 to 2000 ng/mL for alectinib. The bias was within ±3.5 % and ± 5.1 % and precisions ≤5.7 % and ≤ 1.9 % for 2H6-alectinib and alectinib, respectively. By correcting for the interference of natural abundant isotopes of alectinib, 2H6-alectinib plasma concentrations between 1 and 5 pg/mL could be quantified, with bias was within ±15.9 % and precision ≤12.5 % in the presence of 400 ng/mL or 800 ng/mL alectinib. The clinical application was successfully applied to quantify 2H6-alectinib and alectinib in plasma samples from a participant enrolled in a microtracer food-effect study.

Keywords

Alectinib, Food-effect, Lc-ms/ms, Microtracer, Natural isotope interference correction, Pharmacokinetics, Taverne

Citation

van der Heijden, L T, Tibben, M M, Ali, M I M, Aardenburg, L G J, Steeghs, N, Beijnen, J H, Rosing, H & Huitema, A D R 2025, 'An ultra-sensitive liquid chromatography tandem mass spectrometry method for the simultaneous quantification of 2H6-alectinib and alectinib in human plasma to support a microtracer food-effect trial', Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, vol. 1253, 124488. https://doi.org/10.1016/j.jchromb.2025.124488