Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging
Files
Publication date
2016-02-07
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
taverne
Abstract
In early-stage breast-cancer patients, accelerated partial-breast irradiation techniques (APBI) and hypofractionation are increasingly implemented after breast-conserving surgery (BCS). For a safe and effective radiation therapy (RT), the influence of intra-fraction motion during dose delivery becomes more important as associated fraction durations increase and targets become smaller. Current image-guidance techniques are insufficient to characterize local target movement in high temporal and spatial resolution for extended durations. Magnetic resonance imaging (MRI) can provide high soft-tissue contrast, allow fast imaging, and acquire images during longer periods. The goal of this study was to quantify intra-fraction motion using MRI scans from 21 breast-cancer patients, before and after BCS, in supine RT position, on two time scales. High-temporal 2-dimensional (2D) MRI scans (cine-MRI), acquired every 0.3 s during 2 min, and three 3D MRI scans, acquired over 20 min, were performed. The tumor (bed) and whole breast were delineated on 3D scans and delineations were transferred to the cine-MRI series. Consecutive scans were rigidly registered and delineations were transformed accordingly. Motion in sub-second time-scale (derived from cine-MRI) was generally regular and limited to a median of 2 mm. Infrequently, large deviations were observed, induced by deep inspiration, but these were temporary. Movement on multi-minute scale (derived from 3D MRI) varied more, although medians were restricted to 2.2 mm or lower. Large whole-body displacements (up to 14 mm over 19 min) were sparsely observed. The impact of motion on standard RT techniques is likely small. However, in novel hypofractionated APBI techniques, whole-body shifts may affect adequate RT delivery, given the increasing fraction durations and smaller targets. Motion management may thus be required. For this, on-line MRI guidance could be provided by a hybrid MRI/RT modality, such as the University Medical Center Utrecht MRI linear accelerator.
Keywords
Adult, Aged, Algorithms, Breast Neoplasms, Female, Humans, Magnetic Resonance Imaging, Middle Aged, Motion, Radiotherapy, Computer-Assisted, Supine Position, breast radiotherapy, Taverne, Journal Article
Citation
van Heijst, T C F, Philippens, M E P, Charaghvandi, R K, den Hartogh, M D, Lagendijk, JJW, van den Bongard, H J G D & van Asselen, B 2016, 'Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging', Physics in Medicine and Biology, vol. 61, no. 3, pp. 1352-1370. https://doi.org/10.1088/0031-9155/61/3/1352