Increased MR-guided high intensity focused ultrasound (MR-HIFU) sonication efficiency of uterine fibroids after carbetocin administration

Publication date

2022-01-01

Authors

Anneveldt, Kimberley J
van 't Oever, Heleen J
Verpalen, Inez M
Nijholt, Ingrid
Bartels, WilbertISNI 0000000388733745
Dijkstra, Jeroen R
van den Hoed, Rolf D
van 't Veer-Ten Kate, Miranda
de Boer, Erwin
Veersema, SebastiaanISNI 0000000388980113

Editors

Advisors

Supervisors

Document Type

Article
Open Access logo

License

cc_by_nc_nd

Abstract

Purpose: We investigated whether administration of the long-acting uterus stimulant carbetocin increased intra-subject sonication efficiency during Magnetic Resonance image guided High Intensity Focused Ultrasound (MR-HIFU) treatment of uterine fibroids. Method: In this prospective cohort study, thirty women with symptomatic uterine fibroids undergoing MR-HIFU treatment were included between January 2018 and January 2019. Treatment started with three sonications on one side of the uterine fibroid. Subsequently, one ampoule of 1 mL carbetocin (100 µg/mL) was administered intravenously and treatment continued with three sonications on the other side of the uterine fibroid. We compared the intra-subject sonication efficiency, in terms of Energy Efficiency Factor (EEF), thermal dose volume and sonication time to ablate one cm 3 of fibroid tissue, before and after carbetocin administration. Adverse events that occurred within 30 min after carbetocin administration were recorded. Results: Sonication efficiency improved after carbetocin administration as indicated by a significant decrease in EEF and sonication time (p = 0.006 and p = 0.001 respectively), and a significant increase in thermal dose volume reached (p = <0.001). Five women (16.7%) experienced temporary tachycardia, one women in combination with headache, within 30 min after carbetocin administration. Conclusion: Administration of the long-acting uterus stimulant carbetocin improved the MR-HIFU treatment intra-subject sonication efficiency in women with symptomatic uterine fibroids.

Keywords

Efficiency, High-intensity focused ultrasound ablation, MR guided interventional procedures, Myoma, Uterine fibroids, Uterus stimulant, Radiology Nuclear Medicine and imaging

Citation

Anneveldt, K J, van 't Oever, H J, Verpalen, I M, Nijholt, I M, Bartels, W, Dijkstra, J R, van den Hoed, R D, van 't Veer-Ten Kate, M, de Boer, E, Veersema, S, Huirne, J A F, Schutte, J M & Boomsma, M F 2022, 'Increased MR-guided high intensity focused ultrasound (MR-HIFU) sonication efficiency of uterine fibroids after carbetocin administration', European journal of radiology open, vol. 9, 100413, pp. 1-8. https://doi.org/10.1016/j.ejro.2022.100413