Use and Waste of Reconstituted Whole Blood Exchange Transfusions: An 11-year National Observational Study

Publication date

2024-12

Authors

de Winter, Derek P
Lopriore, Enrico
Hulzebos, Christian V
Lukens, Michaël V
Klinkspoor, J H
van Bohemen, Michaela
Besten, Gijs den
De Vooght, K. M KISNI 0000000391368072
Vrancken, Sabine L A G
Trompenaars, Amanda M P

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Objectives: To identify indications for exchange transfusions, assess the use and waste of exchange transfusion products (ie, reconstituted whole blood exchange transfusions), and determine nationwide distribution and prevalence of these transfusions in the Netherlands. Study design: All 9 neonatal intensive care units and 15 non-neonatal intensive care unit hospitals participated in this retrospective, observational, cohort study. We retrieved data on the indications for and use of all exchange transfusion products ordered by participating centers over an 11-year period. Results: A total of 574 patients for whom 1265 products were ordered were included for analyses. Severe ABO (32.6%) and non-ABO (25.2%) immune hemolysis and subsequent hyperbilirubinemia were the most frequent indications. Rare indications were severe leukocytosis in Bordetella pertussis (2.1%) and severe anemia (1.5%). Approximately one-half of all ordered products remained unused. In 278 of 574 neonates (48.4%), ≥1 products were not used, of which 229 (82.7%) were due to the resolving of severe hyperbilirubinemia with further intensification of phototherapy. The overall prevalence of neonates who received an exchange transfusion was 14.6:100 000 liveborn neonates. Conclusions: A considerable proportion of products remained unused, and annually a limited number of patients are treated with an exchange transfusion in the Netherlands, highlighting the rarity of the procedure in the Netherlands.

Keywords

Exchange transfusion, hyperbilirubinemia, pertussis, prevalence, Pediatrics, Perinatology, and Child Health

Citation

de Winter, D P, Lopriore, E, Hulzebos, C V, Lukens, M V, Klinkspoor, J H, van Bohemen, M, Besten, G D, de Vooght, K M K, Vrancken, S L A G, Trompenaars, A M P, Hoffmann-Haringsma, A, Péquériaux, N C V, Andriessen, P, Gijzen, K, van Hillegersberg, J L A M, Zant, J C, van Rossem, M C, Gammeren, A J A V, Weerkamp, F, Counsilman, C E, Knol, F R, Schiering, I A M, Dubbink-Verheij, G H, Verweij, E J T J, de Haas, M & WISE investigators 2024, 'Use and Waste of Reconstituted Whole Blood Exchange Transfusions : An 11-year National Observational Study', The Journal of Pediatrics, vol. 275, 114225. https://doi.org/10.1016/j.jpeds.2024.114225