Hemodynamic Parameters in the Parent Arteries of Unruptured Intracranial Aneurysms Depend on Aneurysm Size and Are Different Compared to Contralateral Arteries: A 7 Tesla 4D Flow MRI Study

Publication date

2024-01

Authors

van Tuijl, R. J.
Timmins, K M
Velthuis, BirgittaORCID 0000-0002-2542-9474ISNI 0000000395231874
van Ooij, Pim
Zwanenburg, Jaco J MORCID 0000-0002-4282-5719
Ruigrok, Ynte M.ORCID 0000-0002-5396-2989ISNI 0000000389818257
van der Schaaf, Irene CISNI 0000000390429582

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by_nc

Abstract

Background: Different Circle of Willis (CoW) variants have variable prevalences of aneurysm development, but the hemodynamic variation along the CoW and its relation to presence and size of unruptured intracranial aneurysms (UIAs) are not well known. Purpose: Gain insight into hemodynamic imaging markers of the CoW for UIA development by comparing these outcomes to the corresponding contralateral artery without an UIA using 4D flow magnetic resonance imaging (MRI). Study Type: Retrospective, cross-sectional study. Subjects: Thirty-eight patients with an UIA, whereby 27 were women and a mean age of 62 years old. Field Strength/Sequence: Four-dimensional phase-contrast (PC) MRI with a 3D time-resolved velocity encoded gradient echo sequence at 7 T. Assessment: Hemodynamic parameters (blood flow, velocity pulsatility index [vPI], mean velocity, distensibility, and wall shear stress [peak systolic (WSSMAX), and time-averaged (WSSMEAN)]) in the parent artery of the UIA were compared to the corresponding contralateral artery without an UIA and were related to UIA size. Statistical Tests: Paired t-tests and Pearson Correlation tests. The threshold for statistical significance was P < 0.05 (two-tailed). Results: Blood flow, mean velocity, WSSMAX, and WSSMEAN were significantly higher, while vPI was lower, in the parent artery relative to contralateral artery. The WSSMAX of the parent artery significantly increased linearly while the WSSMEAN decreased linearly with increasing UIA size. Conclusions: Hemodynamic parameters and WSS differ between parent vessels of UIAs and corresponding contralateral vessels. WSS correlates with UIA size, supporting a potential hemodynamic role in aneurysm pathology. Level of Evidence: 2. Technical Efficacy: Stage 2.

Keywords

aneurysm pathology, hemodynamics, intracranial aneurysm, ipsilateral versus contralateral, wall shear stress, Radiology Nuclear Medicine and imaging

Citation

van Tuijl, R J, Timmins, K M, Velthuis, B K, van Ooij, P, Zwanenburg, J J M, Ruigrok, Y M & van der Schaaf, I C 2024, 'Hemodynamic Parameters in the Parent Arteries of Unruptured Intracranial Aneurysms Depend on Aneurysm Size and Are Different Compared to Contralateral Arteries : A 7 Tesla 4D Flow MRI Study', Journal of Magnetic Resonance Imaging, vol. 59, no. 1, pp. 223-230. https://doi.org/10.1002/jmri.28756