High SNR full brain relaxometry at 7T by accelerated MR-STAT

Publication date

2024-07

Authors

Versteeg, EdwinORCID 0000-0003-3235-3970
Liu, Hongyan
van der Heide, Oscar
Fuderer, MihaORCID 0000-0002-5673-915X
van den Berg, CATORCID 0000-0002-5565-6889
Sbrizzi, AlessandroORCID 0000-0003-3276-4542ISNI 0000000396833383

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Purpose: To demonstrate the feasibility and robustness of the Magnetic Resonance Spin TomogrAphy in Time-domain (MR-STAT) framework for fast, high SNR relaxometry at 7T. Methods: To deploy MR-STAT on 7T-systems, we designed optimized flip-angles using the BLAKJac-framework that incorporates the SAR-constraints. Transmit RF-inhomogeneities were mitigated by including a measured (Formula presented.) -map in the reconstruction. Experiments were performed on a gel-phantom and on five volunteers to explore the robustness of the sequence and its sensitivity to (Formula presented.) inhomogeneities. The SNR-gain at 7T was explored by comparing phantom and in vivo results to MR-STAT at 3T in terms of SNR-efficiency. Results: The higher SNR at 7T enabled two-fold acceleration with respect to current 2D MR-STAT protocols at lower field strengths. The resulting scan had whole-brain coverage, with 1 x 1 x 3 mm3 resolution (1.5 mm slice-gap) and was acquired within 3 min including the (Formula presented.) -mapping. After (Formula presented.) -correction, the estimated T1 and T2 in a phantom showed a mean relative error of, respectively, 1.7% and 4.4%. In vivo, the estimated T1 and T2 in gray and white matter corresponded to the range of values reported in literature with a variation over the subjects of 1.0%–2.1% (WM-GM) for T1 and 4.3%–5.3% (WM-GM) for T2. We measured a higher SNR-efficiency at 7T (R = 2) than at 3T for both T1 and T2 with, respectively, a 4.1 and 2.3 times increase in SNR-efficiency. Conclusion: We presented an accelerated version of MR-STAT tailored to high field (7T) MRI using a low-SAR flip-angle train and showed high quality parameter maps with an increased SNR-efficiency compared to MR-STAT at 3T.

Keywords

magnetic resonance imaging, quantitative imaging, Radiology Nuclear Medicine and imaging

Citation

Versteeg, E, Liu, H, van der Heide, O, Fuderer, M, van den Berg, C A T & Sbrizzi, A 2024, 'High SNR full brain relaxometry at 7T by accelerated MR-STAT', Magnetic Resonance in Medicine, vol. 92, no. 1, pp. 226-235. https://doi.org/10.1002/mrm.30052