Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke

Publication date

2025-06

Authors

Biemans, Camille
van der Heiden, Laura
Veenhof, CindyISNI 0000000391495266
Verschuren, OlafISNI 000000039531790X
Visser-Meily, Johanna MaISNI 0000000387554577
Pisters, MartijnISNI 0000000390868841
Hartman, Yvonne

Editors

Advisors

Supervisors

Document Type

Article

Collections

Open Access logo

License

cc_by

Abstract

Accurate monitoring of physical activity (PA) and sedentary behaviour (SB) is crucial for tailoring interventions aimed at improving movement behaviour. This study evaluated the validity of the pocket-worn RISE device for measuring movement behaviour in community-dwelling patients with stroke. Criterion validity was assessed in a laboratory setting using video recordings. Construct validity was assessed in a free-living setting using the thigh-affixed ActivPAL. In the laboratory setting (25 participants, 66 ± 11.8 years), the RISE device showed good criterion validity for SB and PA. In the free-living setting (19 participants, 73 ± 10.2 years), the RISE device showed good construct validity for SB and PA, though further improvements could enhance the accuracy of individual-level measurements of moderate to vigorous physical activity (MVPA) and prolonged sedentary bouts. The mean absolute percentage error and mean percentage error were below the predefined 20% threshold for SB and PA. Intraclass correlation coefficients (ICCs) for SB and PA showed good reliability, but ICC ranges for prolonged sedentary bouts and MVPA were too broad to draw firm conclusions. These findings indicate the RISE device is well-suited for measuring SB and PA in free-living conditions. With real-time feedback, app compatibility, and pocket-wear convenience, the RISE device shows potential for behavioural interventions targeting movement behaviour in stroke and other chronic conditions.

Keywords

accelerometry, physical activity, sedentary behaviour, validity, wearable electronic devices, Analytical Chemistry, Information Systems, Atomic and Molecular Physics, and Optics, Biochemistry, Instrumentation, Electrical and Electronic Engineering, Journal Article

Citation

Biemans, C F M, van der Heiden, L, Veenhof, C, Verschuren, O W, Visser-Meily, J M A, Pisters, M F & Hartman, Y A W 2025, 'Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke', Sensors, vol. 25, no. 11, 3308. https://doi.org/10.3390/s25113308