Abstract
Background: The clinical dilemma in suspected aortic graft infection (AGI) is how to noninvasively obtain a reliable proof of infection. In addition to confirming the presence of infection, obtaining information regarding the extent of infection to select a proper strategy for reoperation is also necessary. Therefore, developing a more reliable noninvasive physiologic approach to detect infected prostheses is required. F-18-fluorodeoxyglucose positron emission tomography scanning (F-18-FDG PET) has been suggested to have a pivotal role in the detection of AGI. In this study, we assessed the contribution of two (semi) quantitative parameters-maximal standardized uptake value (SUVmax) and tissue-to-background ratio (TBR)-and of two visual parameters-fluorodeoxyglucose (FDG) distribution patterns and visual grading scale-in the final confirmation of the diagnosis of AGI. Methods: Patients with a central aortic prosthetic graft and symptoms clinically suggestive of AGI were gathered from a prospectively maintained database. Included were those who underwent F-18-FDG PET scanning combined with computed tomography angiography and in whom periprosthetic samples were taken at some stage in the diagnostic process. AGI was considered proven in case of a positive culture and compared with a group with negative cultures. Positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. Receiver operating characteristics curves were used to assess the ability of SUVmax and TBR to identify the presence and absence of AGI (ie, accuracy). Results: In 37 of 77 patients with suspected AGI, (18)FDG-PET and perigraft material for culturing was obtained. The tissue culture was positive in 21 of these 37 patients (56.7%). Mean +/- standard deviation SUVmax for proven infection was 8.1 +/- 3.7 (range, 3.6-18.5) and TBR was 5.9 +/- 2.7 (range, 1.7-13.0). The area under the curve for SUVmax was 0.78 (95% confidence interval, 0.63-0.93). A cutoff value of 8 yielded a PPV of 80% and a NPV of 54%. The area under the curve for TBR was 0.70 (95% confidence interval, 0.52-0.87). A cutoff value of 6 yielded a PPV of 73% and NPV of 52%. The PPVs for the visual grading scale and F-18-FDG distribution patterns were 75% and 61%, respectively; the NPVs were 77% and 67%, respectively. Conclusions: Our study, performed in a small sample of patients suspected of AGI, showed that the diagnostic abilities of quantitative and visual F-18-FDG PET parameters are modest.
Keywords
F-18-FDG PET/CT, FDG-PET, FLUORODEOXYGLUCOSE, Taverne, Evaluation Studies, Journal Article
Citation
Saleem, B R, Berger, P, Vaartjes, I, de Keizer, B, Vonken, EPA, Slart, R H J A, de Borst, G J & Zeebregts, C J 2015, 'Modest utility of quantitative measures in F-18-fluorodeoxyglucose positron emission tomography scanning for the diagnosis of aortic prosthetic graft infection', Journal of Vascular Surgery, vol. 61, no. 4, pp. 965-971. https://doi.org/10.1016/j.jvs.2014.11.005