Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR): Benchmark results and consensus guidelines from the STOPSTORM.eu consortium
Publication date
2023-12
Authors
Balgobind, Brian V
Visser, Jorrit
Grehn, Melanie
Marquard Knap, Marianne
de Ruysscher, Dirk
Levis, Mario
Alcantara, Pino
Boda-Heggemann, Judit
Both, Marcus
Cozzi, Salvatore
Editors
Advisors
Supervisors
Document Type
Article
Metadata
Show full item recordCollections
License
cc_by
Abstract
BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established.
Keywords
Cardiac substructures, Contouring benchmark, Organs at risk (OAR), STereotactic Arrhythmia Radioablation (STAR), Stereotactic Body Radiotherapy (SBRT), Ventricular tachycardia (VT), Hematology, Oncology, Radiology Nuclear Medicine and imaging, Journal Article
Citation
Balgobind, B V, Visser, J, Grehn, M, Marquard Knap, M, de Ruysscher, D, Levis, M, Alcantara, P, Boda-Heggemann, J, Both, M, Cozzi, S, Cvek, J, Dieleman, E M T, Elicin, O, Giaj-Levra, N, Jumeau, R, Krug, D, Algara López, M, Mayinger, M, Mehrhof, F, Miszczyk, M, Pérez-Calatayud, M J, van der Pol, L H G, van der Toorn, P-P, Vitolo, V, Postema, P G, Pruvot, E, Verhoeff, J C & Blanck, O 2023, 'Refining critical structure contouring in STereotactic Arrhythmia Radioablation (STAR) : Benchmark results and consensus guidelines from the STOPSTORM.eu consortium', Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology, vol. 189, 109949. https://doi.org/10.1016/j.radonc.2023.109949